Impact of Aortic Valve Regurgitation on Doppler Echocardiographic Parameters in Patients with Severe Aortic Valve Stenosis

Author:

Kandels Joscha1ORCID,Metze Michael1ORCID,Hagendorff Andreas1,Stöbe Stephan1

Affiliation:

1. Klinik und Poliklinik für Kardiologie, Universitätsklinikum Leipzig, Liebigstr. 20, 04103 Leipzig, Germany

Abstract

Background: Diagnosing severe aortic stenosis (AS) depends on flow and pressure conditions. It is suspected that concomitant aortic regurgitation (AR) has an impact on the assessment of AS severity. The aim of this study was to analyze the impact of concomitant AR on Doppler-derived guideline criteria. We hypothesized that both transvalvular flow velocity (maxVAV) and the mean pressure gradient (mPGAV) will be affected by AR, whereas the effective orifice area (EOA) and the ratio between maximum velocity of the left ventricular outflow tract and transvalvular flow velocity (maxVLVOT/maxVAV) will not. Furthermore, we hypothesized that EOA (by continuity equation), and the geometric orifice area (GOA) (by planimetry using 3D transesophageal echocardiography, TEE), will not be affected by AR. Methods and Results: In this retrospective study, 335 patients (mean age 75.9 ± 9.8 years, 44% male) with severe AS (defined by EOA < 1.0 cm2) who underwent a transthoracic and transesophageal echocardiography were analyzed. Patients with a reduced left ventricular ejection fraction (LVEF < 53%) were excluded (n = 97). The remaining 238 patients were divided into four subgroups depending on AR severity, and they were assessed using pressure half time (PHT) method: no, trace, mild (PHT 500–750 ms), and moderate AR (PHT 250–500 ms). maxVAV, mPGAV and maxVLVOT/maxVAV were assessed in all subgroups. Among the four subgroups (no (n = 101), trace (n = 49), mild (n = 61) and moderate AR (n = 27)), no differences were obtained for EOA (no AR: 0.75 cm2 ± 0.15; trace AR: 0.74 cm2 ± 0.14; mild AR: 0.75 cm2 ± 0.14; moderate AR: 0.75 cm2 ± 0.15, p = 0.998) and GOA (no AR: 0.78 cm2 ± 0.20; trace AR: 0.79 cm2 ± 0.15; mild AR: 0.82 cm2 ± 0.19; moderate AR: 0.83 cm2 ± 0.14, p = 0.424). In severe AS with moderate AR, compared with patients without AR, maxVAV (p = 0.005) and mPGAV (p = 0.022) were higher, whereas EOA (p = 0.998) and maxVLVOT/maxVAV (p = 0.243) did not differ. The EOA was smaller than the GOA in AS patients with trace (0.74 cm2 ± 0.14 vs. 0.79 cm2 ± 0.15, p = 0.024), mild (0.75 cm2 ± 0.14 vs. 0.82 cm2 ± 0.19, p = 0.021), and moderate AR (0.75 cm2 ± 0.15 vs. 0.83 cm2 ± 0.14, p = 0.024). In 40 (17%) patients with severe AS, according to an EOA < 1.0 cm2, the GOA was ≥ 1.0 cm2. Conclusion: In severe AS with moderate AR, the maxVAV and mPGAV are significantly affected by AR, whereas the EOA and maxVLVOT/maxVAV are not. These results highlight the potential risk of overestimating AS severity in combined aortic valve disease by only assessing transvalvular flow velocity and the mean pressure gradient. Furthermore, in cases of borderline EOA, of approximately 1.0 cm2, AS severity should be verified by determining the GOA.

Publisher

MDPI AG

Subject

Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3