Dual-Energy Lung Perfusion in Portal Venous Phase CT—A Comparison with the Pulmonary Arterial Phase

Author:

Praël IsabelleORCID,Wuest Wolfgang,Heiss RafaelORCID,Wiesmueller Marco,Kopp Markus,Uder Michael,May Matthias S.ORCID

Abstract

Pulmonary arterial dual-energy (aDE) CT is an established technique for evaluating pulmonary perfusion blood volume (PBV). As DECT protocols are increasingly used for thoraco-abdominal CT, this study assessed image quality and clinical findings in portal–venous phase dual-energy (vDE) CT and compared it to aDE. In 95 patients, vDE-CT was performed using a dual-source scanner (70/Sn150 kV, 560/140 ref.mAs). Pulmonary triggered aDE-CT served as reference (n = 94). PBV was reconstructed using a dedicated algorithm. Mean relative attenuation was measured in the pulmonary trunk, aorta, and segmented lung parenchyma. A distribution ratio (DL) between vessels and parenchyma was calculated to assess the iodine uptake of the lung parenchyma. Subjective overall diagnostic image quality was assessed for PBV images on a five-point Likert scale. Image artifacts were classified into five groups based on scale rating and compared between vDE and aDE. Pathological findings were correlated with the anatomical image datasets. Mean relative attenuation of the lung parenchyma was comparable in both groups (vDE: 23 ± 6 HU and aDE: 22 ± 7 HU), but significantly lower in the vessels of vDE. Therefore, iodine uptake of the lung parenchyma was significantly higher in vDE (DL: 10% vs. 8%, p < 0.01). The subjective overall image quality of the PBV images was comparable (p = 0.5). Rotation and streak artifacts were found in most of the patients (>86%, both p > 0.6). Dual-source artifacts were found in only a few patients in both groups (vDE 5%, aDE 7%, p = 0.5). Recess and subpleural artifacts were increased in vDE (vDE 53/27%, aDE 24/7%, both p < 0.001). Pathological findings were found in 19% of the vDE patients and 59% of the aDE patients. Comparable objective and subjective image quality of lung perfusion can be obtained in vDE and aDE. Iodine uptake of the lung parenchyma is increased in vDE compared to aDE, suggesting an interstitial pooling effect. Knowledge of the different appearances of artifacts will aid in the interpretation of the images. Additional clinical information about the lung parenchyma can be provided by PBV evaluation in vDE.

Publisher

MDPI AG

Subject

Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3