Interrater Agreement and Reliability of PERCIST and Visual Assessment When Using 18F-FDG-PET/CT for Response Monitoring of Metastatic Breast Cancer

Author:

Sørensen Jonas S.ORCID,Vilstrup Mie H.ORCID,Holm JorunORCID,Vogsen MarianneORCID,Bülow Jakob L.,Ljungstrøm Lasse,Braad Poul-ErikORCID,Gerke OkeORCID,Hildebrandt Malene G.ORCID

Abstract

Response evaluation at regular intervals is indicated for treatment of metastatic breast cancer (MBC). FDG-PET/CT has the potential to monitor treatment response accurately. Our purpose was to: (a) compare the interrater agreement and reliability of the semi-quantitative PERCIST criteria to qualitative visual assessment in response evaluation of MBC and (b) investigate the intrarater agreement when comparing visual assessment of each rater to their respective PERCIST assessment. We performed a retrospective study on FDG-PET/CT in women who received treatment for MBC. Three specialists in nuclear medicine categorized response evaluation by qualitative assessment and standardized one-lesion PERCIST assessment. The scans were categorized into complete metabolic response, partial metabolic response, stable metabolic disease, and progressive metabolic disease. 37 patients with 179 scans were included. Visual assessment categorization yielded moderate agreement with an overall proportion of agreement (PoA) between raters of 0.52 (95% CI 0.44–0.66) and a Fleiss kappa estimate of 0.54 (95% CI 0.46–0.62). PERCIST response categorization yielded substantial agreement with an overall PoA of 0.65 (95% CI 0.57–0.73) and a Fleiss kappa estimate of 0.68 (95% CI 0.60–0.75). The difference in PoA between overall estimates for PERCIST and visual assessment was 0.13 (95% CI 0.06–0.21; p = 0.001), that of kappa was 0.14 (95% CI 0.06–0.21; p < 0.001). The overall intrarater PoA was 0.80 (95% CI 0.75–0.84) with substantial agreement by a Fleiss kappa of 0.74 (95% CI 0.69–0.79). Semi-quantitative PERCIST assessment achieved significantly higher level of overall agreement and reliability compared with qualitative assessment among three raters. The achieved high levels of intrarater agreement indicated no obvious conflicting elements between the two methods. PERCIST assessment may, therefore, give more consistent interpretations between raters when using FDG-PET/CT for response evaluation in MBC.

Publisher

MDPI AG

Subject

Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3