Using A-Mode Ultrasound to Assess the Body Composition of Soccer Players: A Comparative Study of Prediction Formulas

Author:

Muntean Paul123,Neagu Monica12ORCID,Amaricai Elena3ORCID,Haragus Horia G.4ORCID,Onofrei Roxana Ramona3ORCID,Neagu Adrian125ORCID

Affiliation:

1. Department of Functional Sciences, Victor Babes University of Medicine and Pharmacy Timisoara, 300041 Timisoara, Romania

2. Center for Modeling Biological Systems and Data Analysis, Victor Babes University of Medicine and Pharmacy Timisoara, 300041 Timisoara, Romania

3. Department of Rehabilitation, Physical Medicine and Rheumatology, Research Center for Assessment of Human Motion, Functionality and Disability, Victor Babes University of Medicine and Pharmacy Timisoara, 300041 Timisoara, Romania

4. Department of Orthopedics, Victor Babes University of Medicine and Pharmacy Timisoara, 300041 Timisoara, Romania

5. Department of Physics and Astronomy, University of Missouri, Columbia, MO 65211, USA

Abstract

For elite athletes, monitoring body composition is important for maximizing performance without health risks. Amplitude (A)-mode ultrasound (AUS) has attracted increasing attention as an alternative to skinfold thickness measurements commonly used for assessing the amount of body fat in athletes. AUS accuracy and precision, however, depend on the formula used to predict body fat percentage (%BF) from subcutaneous fat layer thicknesses. Therefore, this study evaluates the accuracy of the 1-point biceps (B1), 9-sites Parrillo, 3-sites Jackson and Pollock (JP3), and 7-sites Jackson and Pollock (JP7) formulas. Relying on the previous validation of the JP3 formula in college-aged male athletes, we took AUS measurements in 54 professional soccer players (aged 22.9 ± 3.83 y, mean ± SD) and compared the results given by different formulas. The Kruskal–Wallis test indicated significant differences (p < 10−6), and Conover’s post hoc test revealed that the JP3 and JP7 data come from the same distribution, whereas the data given by B1 and P9 differ from all the others. Lin’s concordance correlation coefficients for B1 vs. JP7, P9 vs. JP7, and JP3 vs. JP7 were 0.464, 0.341, and 0.909, respectively. The Bland–Altman analysis indicated mean differences of −0.5 %BF between JP3 and JP7, 4.7 %BF between P9 and JP7, and 3.1 %BF between B1 and JP7. This study suggests that JP7 and JP3 are equally valid, whereas P9 and B1 overestimate %BF in athletes.

Publisher

MDPI AG

Subject

Clinical Biochemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3