Abbreviated Versus Multiparametric Prostate MRI in Active Surveillance for Prostate-Cancer Patients: Comparison of Accuracy and Clinical Utility as a Decisional Tool

Author:

Zattoni Fabio1ORCID,Maresca Silvio2,Dal Moro Fabrizio1,Bednarova Iliana3,Randazzo Gianmarco1ORCID,Basso Giovanni1,Reitano Giuseppe1,Giannarini Gianluca4ORCID,Zuiani Chiara2,Girometti Rossano2

Affiliation:

1. Department Surgery, Oncology and Gastroenterology, Urologic Unit, University of Padova, 35122 Padova, Italy

2. Department of Medicine, Institute of Radiology, University of Udine, Santa Maria della Misericordia University Hospital, 33100 Udine, Italy

3. Department of Breast Radiology, Veneto Institute of Oncology, IRCCS, 35128 Padua, Italy

4. Urology Unit, Santa Maria della Misericordia University Hospital, 33100 Udine, Italy

Abstract

(1) Purpose: To compare the diagnostic accuracy between full multiparametric contrast-enhanced prostate MRI (mpMRI) and abbreviated dual-sequence prostate MRI (dsMRI) in men with clinically significant prostate cancer (csPCa) who were candidates for active surveillance. (2) Materials and Methods: Fifty-four patients with a diagnosis of low-risk PCa in the previous 6 months had a mpMRI scan prior to a saturation biopsy and a subsequent MRI cognitive transperineal targeted biopsy (for PI-RADS ≥ 3 lesions). The dsMRI images were obtained from the mpMRI protocol. The images were selected by a study coordinator and assigned to two readers blinded to the biopsy results (R1 and R2). Inter-reader agreement for clinically significant cancer was evaluated with Cohen’s kappa. The dsMRI and mpMRI accuracy was calculated for each reader (R1 and R2). The clinical utility of the dsMRI and mpMRI was investigated with a decision-analysis model. (3) Results: The dsMRI sensitivity and specificity were 83.3%, 31.0%, 75.0%, and 23.8%, respectively, for R1 and R2. The mpMRI sensitivity and specificity were 91.7%, 31.0%, 83.3%, and 23.8%, respectively, for R1 and R2. The inter-reader agreement for the detection of csPCa was moderate (k = 0.53) and good (k = 0.63) for dsMRI and mpMRI, respectively. The AUC values for the dsMRI were 0.77 and 0.62 for the R1 and R2, respectively. The AUC values for the mpMRI were 0.79 and 0.66 for R1 and R2, respectively. No AUC differences were found between the two MRI protocols. At any risk threshold, the mpMRI showed a higher net benefit than the dsMRI for both R1 and R2. (4) Conclusions: The dsMRI and mpMRI showed similar diagnostic accuracy for csPCa in male candidates for active surveillance.

Publisher

MDPI AG

Subject

Clinical Biochemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3