Combined 3D Endoanal Ultrasound and Transperineal Ultrasound Improves the Detection of Anal Sphincter Defects

Author:

Carter Dan12,Ram Edward23,Engel Tal12ORCID

Affiliation:

1. Department of Gastroenterology, Chaim Sheba Medical Center, Tel Hasomer, Ramat Gan 5266202, Israel

2. Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel

3. Department Surgery B, Chaim Sheba Medical Center, Ramat Gan 5266202, Israel

Abstract

Introduction: Anal sphincter injury, mainly due to obstetric or iatrogenic etiology, is the most common cause of fecal incontinence (FI). Three-dimensional endoanal ultrasound (3D EAUS) is used for assessment of the integrity and the degree of anal muscle injury. However, 3D EAUS accuracy may be hampered by regional acoustic effects, such as intravaginal air. Therefore, our aim was to examine whether a combination of transperineal ultrasound (TPUS) and 3D EAUS would improve the accuracy of detection of anal sphincter injury. Methods: We prospectively performed 3D EAUS followed by TPUS in every patient evaluated for FI in our clinic between January 2020 and January 2021. The diagnosis of anal muscle defects was assessed in each ultrasound technique by two experienced observers that were blinded to each other’s assessments. Interobserver agreement for the results of the 3D EAUS and the TPUS exams was examined. A final diagnosis of anal sphincter defect was based on the results of both ultrasound methods. Discordant results were re-analyzed by the two ultrasonographers for a final consensus on the presence or absence of defects. Results: A total of 108 patients underwent ultrasonographic assessment due to FI (mean age 69 ± 13). Interobserver agreement for the diagnosis of tear on EAUS and TPUS was high (83%) with Cohen’s kappa of 0.62. EAUS confirmed anal muscle defects in 56 patients (52%), while TPUS confirmed them in 62 patients (57%). The final consensus agreed on the diagnosis of 63 (58%) muscular defects and 45 (42%) normal exams. The Cohen’s kappa coefficient of agreement between the results of the 3D EAUS and the final consensus was 0.63. Conclusions: The combination of 3D EAUS and TPUS improved the detection of anal muscular defects. The application of both techniques for the assessment of the anal integrity should be considered in every patient going through ultrasonographic assessment for anal muscular injury.

Publisher

MDPI AG

Subject

Clinical Biochemistry

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3