A Pilot Study of the Reliability and Agreement of Heart Rate, Respiratory Rate and Short-Term Heart Rate Variability in Elite Modern Pentathlon Athletes

Author:

Hoffmann BartoszORCID,Flatt Andrew A.ORCID,Silva Luiz Eduardo VirgilioORCID,Młyńczak MarcelORCID,Baranowski Rafał,Dziedzic Ewelina,Werner Bożena,Gąsior Jakub S.

Abstract

Research on reliability of heart rate variability (HRV) parameters in athletes has received increasing attention. The aims of this study were to examine the inter-day reliability of short-term (5 min) and ultra-short-term (1 min) heart rate (HR), respiratory rate (RespRate) and HRV parameters, agreement between short-term and ultra-short-term parameters, and association between differences in HR, RespRate and HRV parameters in elite modern pentathletes. Electrocardiographic recordings were performed in stable measurement conditions with a week interval between tests. Relative reliability was evaluated by intra-class correlation coefficients, absolute reliability was evaluated by within-subject coefficient of variation, and agreement was evaluated using Bland–Altman (BA) plot with limits of agreement and defined a priori maximum acceptable difference. Short-term HR, RespRate, log transformed (ln) root mean square of successive normal-to-normal interval differences (lnRMSSD), ln high frequency (lnHF) and SD2/SD1 HRV indices and ultra-short-term HR, RespRate and lnRMSSD presented acceptable, satisfactory inter-day reliability. Although there were no significant differences between short-term and ultra-short-term HR, RespRate and lnRMSSD, no parameter showed acceptable differences with BA plots. Differences in time-domain and non-linear HRV parameters were more correlated with differences in HR than with differences in RespRate. Inverse results were observed for frequency-domain parameters. Short-term HR, RespRate, lnRMSSD, lnHF, and SD2/SD1 and ultra-short-term HR, RespRate and lnRMSSD could be used as reliable parameters in endurance athletes. However, practitioners should interpret changes in HRV parameters with regard to concomitant differences in HR and RespRate and caution should be taken before considering 5 min and 1 min parameters as interchangeable.

Publisher

MDPI AG

Subject

Clinical Biochemistry

Cited by 18 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3