18F-FDG PET Is Not Inferior to 68Ga-PSMA PET for Detecting Biochemical Recurrent Prostate Cancer with a High Gleason Score: A Head-to-Head Comparison Study

Author:

Xu Lian12,Chen Ruohua2,Yu Xiaofeng2,Liu Jianjun2,Wang Yuetao13

Affiliation:

1. Department of Nuclear Medicine, The Third Affiliated Hospital of Soochow University, Changzhou 213003, China

2. Department of Nuclear Medicine, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200025, China

3. Institute of Clinical Translation of Nuclear Medicine and Molecular Imaging, Soochow University, Changzhou 213003, China

Abstract

Previous studies have indicated that 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) in biochemical recurrence (BCR) patients with poorly differentiated prostate adenocarcinoma had higher diagnostic sensitivity than those with well differentiated adenocarcinoma, but whether the performance of FDG PET can achieve the effect of prostate-specific membrane antigen (PSMA) PET in BCR patients with a high Gleason score remains poorly understood. This study aimed to compare the efficacies of 18F-FDG PET/CT and 68Ga-PSMA PET/CT for BCR patients and evaluate whether 18F-FDG PET was not inferior to 68Ga-PSMA PET for detecting BCR with a high Gleason score. This was a retrospective, head-to-head comparative study completed at Ren Ji Hospital between May 2018 and June 2021. Patients underwent both 18F-FDG and 68Ga-PSMA PET/CT. The detection rate of BCR at the patient level and at the anatomical region level was evaluated. In total, 145 patients were enrolled in this study. 18F-FDG PET/CT (24.1%, 35/145) had lower detection rates than 68Ga-PSMA PET/CT (59.3%, 86/145; p < 0.001) at the patient level and at any anatomical region (p < 0.05). The PSA level (p < 0.001, OR = 11.026, 95% CI: 3.214–37.824) and the Gleason score (p < 0.001, OR = 20.227, 95% CI: 5.741–71.267) were independent predictive factors of the detection rate on 18F-FDG PET/CT, while the PSA level (p < 0.001, OR = 4.862, 95% CI: 2.338–10.110) was the only predictor of the detection rate on 68Ga-PSMA PET/CT. 18F-FDG PET/CT had a similar detection rate as 68Ga-PSMA PET/CT in patients with a Gleason score of 9 at the patient level (64.3% vs. 71.4%, p = 0.567) and any anatomical region (all p > 0.05), but 18F-FDG PET/CT had a lower detection rate than 68Ga-PSMA PET/CT in patients with a Gleason score of 6–8. 18F-FDG PET is not inferior to 68Ga-PSMA PET for detecting BCR with a Gleason score of 9; therefore, 18F-FDG PET/CT could be considered in BCR patients with a Gleason score of 9. However, 68Ga-PSMA is a better tracer than 18F-FDG in PET/CT for treatment decision making in BCR patients with a Gleason score of 6–8.

Funder

National Key R&D Program of China

National Natural Science Foundation of China

Publisher

MDPI AG

Subject

Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3