Optical Methods for Optimizing Fluorescence Imaging Field of View and Image Quality in Surgical Guidance Procedures

Author:

Seo Jeongmin12,Park Jina12,Yoon Kicheol12,Lee Sangyun3ORCID,Kim Minchan2,Ryu Seung Yeob24,Kim Kwang Gi245ORCID

Affiliation:

1. Premedicine Course & Department of Medicine, College of Medicine, Gachon University, 8-13, 3 Dokjom-ro, Namdong-gu, Incheon 21565, Republic of Korea

2. Medical Devices R&D Center, Gachon University Gil Medical Center, 21, 774 Beon-gil, Namdong-daero, Namdong-gu, Incheon 21565, Republic of Korea

3. Department of Radiological Science, Dongnam Health University, 50 Cheoncheon-ro 74 gil Jangan-gu, Suwon 16328, Republic of Korea

4. Department of Biohealth & Medical Engineering Major and Biomedical Engineering, Gachon University, 1342 Seongnamdaero, Sujeong-gu, Seongnam 13120, Republic of Korea

5. Department of Health Sciences and Technology, Gachon Advanced Institute for Health Sciences and Technology (GAIHST), Gachon University, 38-13, 3 Dokjom-ro, Namdong-gu, Incheon 21565, Republic of Korea

Abstract

Cancer surgery is aimed at complete tumor resection and accurate lymph node detection. However, numerous blood vessels are distributed within the tumor, and the colors of the tumor, blood vessels, and lymph nodes are similar, making observations with the naked eye difficult. Therefore, tumors, blood vessels, and lymph nodes can be monitored via color classification using an operating microscope to induce fluorescence emission. However, as the beam width of the LED required to induce fluorescence emission is narrow and the power loss of the beam is significant at a certain working distance, there are limitations to inducing fluorescence emission, and light reflection occurs in the observation image, obstructing the view of the observation area. Therefore, the removal of reflected light is essential to avoid missing the diagnosis of the lesion under observation. This paper proposes the use of a beam mirror and polarizing filter to increase the beam width and beam intensity. The refraction and reflection effects of the beam were utilized using the beam mirror, and the rotation angle of the polarizing filter was adjusted to remove light reflection. Consequently, the minimum beam power using the beam mirror was 10.9 mW, the beam width was doubled to 40.2°, and more than 98% of light reflection was removed at 90° and 270°. With light reflection effectively eliminated, clear observation of lesions is possible. This method is expected to be used effectively in surgical, procedural, and diagnostic departments.

Funder

GRRC program of Gyeonggi province

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3