Correlation between a New Point-Shear Wave Elastography Device (X+pSWE) with Liver Histology and 2D-SWE (SSI) for Liver Stiffness Quantification in Chronic Liver Disease

Author:

Garcovich Matteo1ORCID,Paratore Mattia1ORCID,Riccardi Laura1,Zocco Maria Assunta1ORCID,Ainora Maria Elena1ORCID,Mingrone Geltrude23,Gasbarrini Antonio1ORCID,Pompili Maurizio45

Affiliation:

1. Medicina Interna e Gastroenterologia, CEMAD Digestive Disease Center, Fondazione Policlinico Universitario A. Gemelli IRCCS, Largo A. Gemelli 8, 00168 Rome, Italy

2. Dipartimento di Medicina e Chirurgia Traslazionale, Università Cattolica del Sacro Cuore, 00168 Rome, Italy

3. U.O.C. Patologie dell’Obesità, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy

4. Internal Medicine and Gastroenterology-Hepatology Unit, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy

5. Translational Medicine and Surgery Department, Università Cattolica del Sacro Cuore, 00168 Rome, Italy

Abstract

Background: The aim of this study was to investigate the feasibility, the correlation with previously validated 2D-SWE by supersonic imagine (SSI), and the accuracy in fibrosis-staging of a novel point shear-wave elastography device (X+pSWE) in patients with chronic liver disease. Methods: This prospective study included 253 patients with chronic liver diseases, without comorbidities potentially affecting liver stiffness. All patients underwent X+pSWE and 2D-SWE with SSI. Among them 122 patients also underwent liver biopsy and were classified according to histologic fibrosis. Agreement between the equipment was assessed with Pearson coefficient and Bland–Altman analysis, while receiver operator characteristic curve (ROC) analysis with Youden index was used to establish thresholds for fibrosis staging. Results: A very good correlation was found between X+pSWE and 2D-SWE with SSI (r2 = 0.94; p < 0.001), with X+pSWE average liver stiffness values 0.24 kPa lower than those obtained with SSI. AUROC of X+pSWE for the staging of significant fibrosis (F2), severe fibrosis (F3) and cirrhosis (F4) using SSI as a reference standard was 0.96 (95% CI, 0.93–0.99), 0.98 (95% CI, 0.97–1) and 0.99 (95% CI, 0.98–1), respectively. The best cut-off values for diagnosing fibrosis ≥F2, ≥F3 and F4 were, respectively, 6.9, 8.5 and 12 for X+pSWE. According to histologic classification, X+pSWE correctly identified 93 out of 113 patients (82%) for F ≥ 2 and 101 out of 113 patients (89%) for F ≥ 3 using the aforementioned cut-off values. Conclusion: X+pSWE is a useful novel non-invasive technique for staging liver fibrosis in patients with chronic liver disease.

Publisher

MDPI AG

Subject

Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3