Analysis of Temperatures Generated during Conventional Laser Irradiation of Root Canals—A Finite Element Study

Author:

Stănuși Adrian1,Popa Dragoş2,Ionescu Mihaela3,Cumpătă Cristian4,Petrescu Gabriel5,Ţuculină Mihaela1ORCID,Dăguci Constantin6,Diaconu Oana1,Gheorghiță Lelia1,Stănuşi Andreea7ORCID

Affiliation:

1. Department of Endodontics, Faculty of Dental Medicine, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania

2. Faculty of Mechanics, University of Craiova, 200349 Craiova, Romania

3. Department of Medical Informatics and Biostatistics, Faculty of Medicine, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania

4. Department of Oral and Maxillofacial Surgery, Faculty of Dental Medicine, University Titu Maiorescu of Bucharest, 67A Gheorghe Petrascu Str., 031593 Bucharest, Romania

5. Department of Oral and Maxillofacial Surgery, Faculty of Dental Medicine, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania

6. Department of Oro-Dental Prevention, Faculty of Dental Medicine, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania

7. Department of Prosthodontics, Faculty of Dental Medicine, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania

Abstract

The success of endodontic treatment is dependent on the removal of bacteria. A modern strategy to reduce bacterial load is laser irradiation. During this procedure, there is a local increase in temperature with possible side effects. The aim of this study was to determine the thermal behavior of a maxillary first molar when performing the conventional irradiation technique using a diode laser. For this study, a 3D virtual model of a maxillary first molar was created. The preparation of the access cavity, the rotary instrumentation of the palatal root canal and the laser irradiation protocol were simulated. The model was exported in a finite element analysis program where the temperature and heat flux were studied. Temperature and heat flux maps were obtained, and the temperature increase on the internal wall of the root canal was analyzed. The maximum temperature value exceeded 400 °C and was maintained for less than 0.5 s. The obtained temperature maps support the bactericidal effect of diode laser and the limitation of damage to surrounding tissues. On internal root walls, the temperature reached several hundred degrees Celsius, but for very short durations. Conventional laser irradiation is an adjuvant method of decontamination of the endodontic system.

Funder

University of Medicine and Pharmacy of Craiova

Publisher

MDPI AG

Subject

Clinical Biochemistry

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3