Comparison of a Presbyopia-Correcting Supplementary Intraocular Lens Combination and a Capsular-Bag Lens: An In Vitro Study

Author:

Khoramnia Ramin1ORCID,Baur Isabella Diana1ORCID,Yan Weijia1ORCID,Łabuz Grzegorz1,Auffarth Gerd Uwe1ORCID

Affiliation:

1. David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany

Abstract

We evaluated the optical quality of two approaches to trifocality: polypseudophakia versus monopseudophakia. The combination (polypseudophakia) of a monofocal Basis Z B1AWY0 and AddOn Trifocal A4DW0M intraocular lens (IOL) was compared to using one Basis Z Trifocal B1EWYN IOL, all from 1stQ GmbH. In both approaches, we measured modulation transfer function (MTF) and Strehl Ratio (SR) values at 3.0 and 4.5 mm pupil sizes. We determined the through-focus (TF) MTF at 25, 50 and 100 lp/mm for the 3 mm aperture. United States Air Force (USAF) target images were recorded. MTF measurement of the trifocal lens and the combined monofocal and trifocal AddOn IOL showed good performance at the far and near focus for the 3 mm aperture. For the 4.5 mm aperture the MTF improved for the far focus but decreased for the intermediate and near focus. TF MTF showed better contrast at the far focus for the polypseudophakic setup but at the expense of the efficiency at the near focus. However, the USAF chart images revealed only minimal differences between both approaches. The optical quality of the polypseudophakic approach was not affected by the presence of two IOLs instead of one and proved to be comparable with the performance of one capsular-bag-fixated trifocal IOL. Differences between the single vs. two-lens approach seen in the TF MTF analysis could be attributed to the optical design that varied between the trifocal models.

Funder

1stQ GmbH

Klaus Tschira Foundation, Heidelberg, Germany

Rahel Goitein-Straus-Program of the Faculty of Medicine of Heidelberg University

Publisher

MDPI AG

Subject

Clinical Biochemistry

Reference38 articles.

1. Multifocal intraocular lenses and extended depth of focus intraocular lenses;Breyer;Asia-Pac. J. Ophthalmol.,2017

2. Evidence-based guidelines for cataract surgery: Guidelines based on data in the European Registry of Quality Outcomes for Cataract and Refractive Surgery database;Barry;J. Cataract Refract. Surg.,2012

3. Duet procedure to achieve reversible trifocality;Khoramnia;Der Ophthalmologe 2020, 117, 999–1004. Correction in Der Ophthalmol. Z. Dtsch. Ophthalmol. Ges.,2020

4. Interlenticular opacification: Clinicopathological correlation of a complication of posterior chamber piggyback intraocular lenses;Gayton;J. Cataract Refract. Surg.,2000

5. Analysis of elements of interlenticular opacification;Werner;Am. J. Ophthalmol.,2002

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献