Dorsal Root Ganglia Volume—Normative Values, Correlation with Demographic Determinants and Reliability of Three Different Methods of Volumetry

Author:

Kronlage Moritz,Fischer Thomas David,Behnisch Rouven,Schwarz DanielORCID,Bäumer Philipp,Schwehr Veronique,Heiland Sabine,Bendszus Martin,Godel Tim

Abstract

Background: Dorsal root ganglia (DRG) volume assessment by MR-Neurography (MRN) has evolved to an important imaging marker in the diagnostic workup of various peripheral neuropathies and pain syndromes. The aim of this study was (1) to assess normal values of DRG volume and correlations with demographic determinants and (2) to quantify the inter-reader and inter-method reliability of three different methods of DRG volumetry. Methods: Sixty healthy subjects (mean age: 59.1, range 23–79) were examined using a 3D T2-weighted MRN of the lumbosacral plexus at 3 Tesla. Normal values of DRG L3 to S2 were obtained after exact volumetry based on manual 3D segmentation and correlations with demographic variables were assessed. For the assessment of inter-reader and inter-method reliability, DRG volumes in a subset of 25 participants were measured by two independent readers, each applying (1) exact volumetry based on 3D segmentation, (2) axis-corrected, and (3) non-axis-corrected volume estimation. Intraclass correlation coefficients were reported and the Bland–Altman analysis was conducted. Results: Mean DRG volumes ranged from 124.8 mm3 for L3 to 323.3 mm3 for S1 and did not differ between right and left DRG. DRG volume (mean of L3 to S1) correlated with body height (r = 0.42; p = 0.0008) and weight (r = 0.34; p = 0.0087). DRG of men were larger than of women (p = 0.0002); however, no difference remained after correction for body height. Inter-reader reliability was high for all three methods but best for exact volumetry (ICC = 0.99). While axis-corrected estimation was not associated with a relevant bias, non-axis-corrected estimation systematically overestimated DRG volume by on average of 15.55 mm3 (reader 1) or 18.00 mm3 (reader 2) when compared with exact volumetry. Conclusion: The here presented normal values of lumbosacral DRG volume and the correlations with height and weight may be considered in future disease specific studies and possible clinical applications. Exact volumetry was most reliable and should be considered the gold standard. However, the reliability of axis-corrected and non-axis-corrected volume estimation was also high and might still be sufficient, depending on the degree of the required measurement accuracy.

Publisher

MDPI AG

Subject

Clinical Biochemistry

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3