Calculation of Aortic VAlve and LVOT Areas by a Modified Continuity Equation Using Different Echocardiography Methods: The CAVALIER Study

Author:

Ruf Tobias FriedrichORCID,Cannard Béatrice Elise,Strasser Ruth H.,Linke Axel,Sveric Krunoslav M.

Abstract

Background: The area of the left ventricular outflow tract (ALVOT) represents a major component of the continuity equation (CE), which is, i.a., crucial to calculate the aortic valve (AV) area (AAV). The ALVOT is typically calculated using 2D echo assessments as the measured anterior–posterior (a/p) extension, assuming a round LVOT base. Anatomically, however, usually an elliptical shape of the LVOT base is present, with the long diameter extending from the medial–lateral axis (m/l), which is not recognized by two-dimensional (2D) echocardiography. Objective: We aimed to compare standard and three-dimensional (3D)-echocardiography-derived ALVOT calculation and its use in a standard CE (CEstd) and a modified CE (CEmod) to calculate the AAV vs. computed tomography (CT) multi-planar reconstruction (MPR) measurements of the anatomical ALVOT, and AAV, respectively. Methods: Patients were selected if 3D transthoracic echocardiography (TTE), 3D transesophageal echocardiography (TEE), and cardiac CT were all performed, and imaging quality was adequate. The ALVOT was assessed using 2D calculation, (a/p only), 3D-volume MPR, and 3D-biplane calculation (a/p and m/l). AAV was measured using both CEstd and CEmod, and 3D-volume MPR. Data were compared to corresponding CT analyses. Results: From 2017 to 2018, 107 consecutive patients with complete and adequate imaging data were included. The calculated ALVOT was smaller when assessed by 2D- compared to both 3D-volume MPR and 3D-biplane calculation. Calculated AAV was correspondingly smaller in CEstd compared to CEmod or 3D-volume MPR. The ALVOT and AAV, using data from 3D echocardiography, highly correlated and were congruent with corresponding measurements in CT. Conclusion: Due to the elliptic shape of the LVOT, use of measurements and calculations based on 2D echocardiography systematically underestimates the ALVOT and dependent areas, such as the AAV. Anatomically correct assessment can be achieved using 3D echocardiography and adapted calculations, such as CEmod.

Publisher

MDPI AG

Subject

Clinical Biochemistry

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3