Quantitative CT Texture Analysis of COVID-19 Hospitalized Patients during 3–24-Month Follow-Up and Correlation with Functional Parameters

Author:

Fanni Salvatore Claudio1,Volpi Federica1,Colligiani Leonardo1ORCID,Chimera Davide2,Tonerini Michele3,Pistelli Francesco2ORCID,Pancani Roberta2ORCID,Airoldi Chiara4ORCID,Bartholmai Brian J.5ORCID,Cioni Dania1ORCID,Carrozzi Laura2,Neri Emanuele1ORCID,De Liperi Annalisa6,Romei Chiara6

Affiliation:

1. Department of Translational Research, Academic Radiology, University of Pisa, 56126 Pisa, Italy

2. Pneumology Unit, Pisa University Hospital, 56124 Pisa, Italy

3. Department of Surgical, Medical, Molecular and Critical Area Pathology, University of Pisa, 56124 Pisa, Italy

4. Department of Translational Medicine, University of Eastern Piemonte, 28100 Novara, Italy

5. Division of Radiology, Mayo Clinic, Rochester, MN 55905, USA

6. 2nd Radiology Unit, Department of Diagnostic Imaging, Pisa University-Hospital, Via Paradisa 2, 56124 Pisa, Italy

Abstract

Background: To quantitatively evaluate CT lung abnormalities in COVID-19 survivors from the acute phase to 24-month follow-up. Quantitative CT features as predictors of abnormalities’ persistence were investigated. Methods: Patients who survived COVID-19 were retrospectively enrolled and underwent a chest CT at baseline (T0) and 3 months (T3) after discharge, with pulmonary function tests (PFTs). Patients with residual CT abnormalities repeated the CT at 12 (T12) and 24 (T24) months after discharge. A machine-learning-based software, CALIPER, calculated the CT percentage of the whole lung of normal parenchyma, ground glass (GG), reticulation (Ret), and vascular-related structures (VRSs). Differences (Δ) were calculated between time points. Receiver operating characteristic (ROC) curve analyses were performed to test the baseline parameters as predictors of functional impairment at T3 and of the persistence of CT abnormalities at T12. Results: The cohort included 128 patients at T0, 133 at T3, 61 at T12, and 34 at T24. The GG medians were 8.44%, 0.14%, 0.13% and 0.12% at T0, T3, T12 and T24. The Ret medians were 2.79% at T0 and 0.14% at the following time points. All Δ significantly differed from 0, except between T12 and T24. The GG and VRSs at T0 achieved AUCs of 0.73 as predictors of functional impairment, and area under the curves (AUCs) of 0.71 and 0.72 for the persistence of CT abnormalities at T12. Conclusions: CALIPER accurately quantified the CT changes up to the 24-month follow-up. Resolution mostly occurred at T3, and Ret persisting at T12 was almost unchanged at T24. The baseline parameters were good predictors of functional impairment at T3 and of abnormalities’ persistence at T12.

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3