Abstract
Diagnostic laboratory tools are essential to keep everyone safe and track newly emerging variants; on the other hand, “filter” screening tests recognizing positivity are valuable tools to avoid hectic laboratory work that, besides COVID-19, are also part of the routine. Therefore, complementary assays, such as rapid antigen tests (RATs), are essential in controlling and monitoring virus spread within the community, especially in the asymptomatic population. A subset of nasopharyngeal swab specimens resulted in SARS-CoV-2 positive and investigated for genomic characterization were used for RAT validation. RATs were performed immediately after sampling, following the manufacturer’s instructions (reading at 15 min). RT-PCRs were carried out within 24 h of specimens’ collection. Out of 603 patients, 145 (24.05%) tested positive by RT-PCR and RAT and 451 (74.79%) tested negative by both methods; discordant results (RT-PCR+/RAT− or RT-PCR−/RAT+) were obtained in 7 patients (1.16%). RATs’ overall specificity and sensitivity were 96.03% (95%CI: 91.55–98.53%) and 99.78% (95%CI: 98.77–99.99%), respectively, taking RT-PCR as the reference. Overall, RAT negative predictive value was 98.69% (95%CI 97.17–99.40%). The GeneFinder COVID-19 Ag Plus Rapid Test performed well as a screening test for early diagnosis of COVID-19, especially in asymptomatic subjects. The data suggested that patients with RT-PCR-proven COVID-19 testing negative by RAT are unlikely to be infectious. GeneFinder COVID-19 Ag Plus Rapid Test also works on variants of concern (VOC) delta and omicron BA.1 and BA.2.
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献