Abstract
Adequate bowel cleansing is essential for high-quality colonoscopy. Recently, a new very low-volume 1 litre (1L) polyethylene glycol (PEG) plus ascorbate solution (ASC) has been introduced. Our aims were to assess the effectiveness and tolerability of this product compared to low-volume 2L PEG-ASC and high-volume 4L PEG solutions, in a real-life setting. In six endoscopy units in Sweden, outpatients undergoing colonoscopy were either prescribed solutions according to local routines, or the very low-volume solution in split dose regimen. Bowel cleansing effectiveness and patient experience was assessed using the Boston Bowel preparation scale (BBPS) and a patient questionnaire. A total of 1098 patients (mean age 58 years, 52% women) were included. All subsegment and the total BBPS scores were significantly greater for 1L PEG-ASC in comparison to other solutions (p < 0.05 for 1L PEG-ASC and 4L PEG for transverse and left colon, otherwise p < 0.001). Nausea was more frequent with 1L PEG-ASC compared to 2L PEG-ASC (p < 0.001) and vomiting were more often reported compared to both other solutions (p < 0.01 and p < 0.05 for 2L PEG-ASC and 4L PEG, respectively). Smell, taste, and total experience was better for 1L PEG-ASC compared to 4L PEG (p < 0.001), and similar compared to the 2L PEG-ASC. In conclusion, 1L PEG-ASC leads to better bowel cleansing compared to 2L PEG-ASC or 4L PEG products, with similar or greater patient satisfaction.
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献