SEM Evaluation of Marginal Adaptation E-Max Crowns Manufactured by Printing-Pressed and Milling

Author:

Ispas Ana1,Moldovan Marioara2ORCID,Cuc Stanca2ORCID,Prodan Doina2,Bacali Cecilia1,Petean Ioan3ORCID,Buduru Smaranda1ORCID,Manziuc Manuela1ORCID,Iosif Laura4ORCID

Affiliation:

1. Department of Prosthodontics, Faculty of Dental Medicine, “Iuliu Hatieganu” University of Medicine and Pharmacy, 400006 Cluj-Napoca, Romania

2. Raluca Ripan Institute for Research in Chemistry, Babes-Bolyai University, 30 Fantanele Street, 400294 Cluj-Napoca, Romania

3. Faculty of Chemistry and Chemical Engineering, Babes-Bolyai University, 11 Arany Janos Street, 400028 Cluj-Napoca, Romania

4. Department of Prosthodontics, Faculty of Dental Medicine, “Carol Davila” University of Medicine and Pharmacy, 010221 Bucharest, Romania

Abstract

Dental crown marginal adaptation is a matter of the success of dental restoration treatment. Nowadays, there are many technological ways for crown manufacturing, such as tridimensional printing of an exactly desired shape through CAD-assisted systems and the appropriate shape milling of a predesigned bulk crown. Both methods are developed for patient benefits. The current research aims to investigate the marginal adaptation of E-Max crowns manufactured by printing-pressed and milling methods. The in vitro cementation procedures were effectuated on healthy teeth extracted for orthodontic purposes according to the standard procedures and the marginal adaptation was investigated with SEM microscopy. The restoration overview was inspected at a magnification of 100× and the microstructural details at 400×. The integrity of marginal adaptation was properly inspected in identical samples on segments of 2 mm from each buccal, palatal, distal and mesial side. The obtained results reveal a good marginal adaptation for all samples, with some particularities. The statistical analysis shows that the best values of the marginal adaptation were obtained for vestibular/buccal and palatal sides of the teeth being situated around 90–95%, while the values obtained for distal and mesial sides are slightly lower such as 80–90%. Furthermore, it was observed that the milled crowns presents better marginal adaptations than the printed-pressed ones, sustained by the statistical p < 0.05. This indicates that the milling process allows a better fit of the crown to the tooth surface and preserves the integrity of the bonding cement layer.

Funder

UEFISCDI

Publisher

MDPI AG

Subject

Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3