Noise in computed tomography (CT) is inevitably generated, which lowers the accuracy of disease diagnosis. The non-local means approach, a software technique for reducing noise, is widely used in medical imaging. In this study, we propose a noise reduction algorithm based on fast non-local means (FNLMs) and apply it to CT images of a phantom created using 3D printing technology. The self-produced phantom was manufactured using filaments with similar density to human brain tissues. To quantitatively evaluate image quality, the contrast-to-noise ratio (CNR), coefficient of variation (COV), and normalized noise power spectrum (NNPS) were calculated. The results demonstrate that the optimized smoothing factors of FNLMs are 0.08, 0.16, 0.22, 0.25, and 0.32 at 0.001, 0.005, 0.01, 0.05, and 0.1 of noise intensities, respectively. In addition, we compared the optimized FNLMs with noisy, local filters and total variation algorithms. As a result, FNLMs showed superior performance compared to various denoising techniques. Particularly, comparing the optimized FNLMs to the noisy images, the CNR improved by 6.53 to 16.34 times, COV improved by 6.55 to 18.28 times, and the NNPS improved by 10−2 mm2 on average. In conclusion, our approach shows significant potential in enhancing CT image quality with anthropomorphic phantoms, thus addressing the noise issue and improving diagnostic accuracy.
Funder
National Research Foundation
Gachon University
Reference69 articles.
1. Principles of computer assisted tomography (CAT) in radiographic and radioisotopic imaging;Brooks;Phys. Med. Biol.,1976
2. Otomo, N., Funao, H., Yamanouchi, K., Isogai, N., and Ishii, K. (2022). Computed Tomography-Based Navigation System in Current Spine Surgery: A narrative Review. Medicina, 58.
3. Phase, B.V. (2006). Health Risks from Exposure to Low Levels of Ionizing Radiation, The British Institute of Radiology.
4. CT image denoising using NLM and its method noise thresholding;Diwakar;Multimed. Tool. Appl.,2020
5. Electronic noise in CT detectors: Impact on image noise and artifacts;Duan;AJR Am. J. Roentgenol.,2013