The INVISION Talar Component in Revision Total Ankle Arthroplasty: Analysis of Early Outcomes

Author:

Valan Bruno1ORCID,Anastasio Albert T.1ORCID,Kim Billy2,Krez Alexandra1,Wu Kevin A.1ORCID,Talaski Grayson M.3,Nunley James1,DeOrio James K.1,Easley Mark E.1,Adams Samuel B.1

Affiliation:

1. Division of Foot and Ankle, Department of Orthopaedic Surgery, Duke University School of Medicine, Durham, NC 27710, USA

2. Department of Orthopaedic Surgery, Hospital for Special Surgery, New York City, NY 10021, USA

3. Department of Orthopedics and Rehabilitation, University of Iowa, Iowa City, IA 52242, USA

Abstract

Introduction: Launched in 2018 for revision total ankle arthroplasty (rTAA), the INVISION talar component addresses subsidence when poor talar bone stock is present. Due to the recency of the market-availability of the INVISION, studies evaluating its efficacy are lacking. This study presents the first analysis of early-term outcomes of patients undergoing rTAA with the INVISION talar component. Methods: This was a single-center, retrospective review of 28 patients undergoing rTAA with the INVISION talar component and INBONE II tibial component performed between 2018 and 2022. Data on preoperative characteristics, postoperative complications, secondary procedures, and survivorship were collected. The primary outcome measures were rates of major complications, re-operation, and implant failure. Secondary outcomes included post-operative changes in varus and valgus alignment of the tibia and talus. Results: The most common secondary procedures performed with rTAA were medial malleolus fixation (n = 22, 78.6%) and gastrocnemius recession (n = 14, 50%). Overall, 10.7% (n = 3) of patients underwent reoperation and 14.3% (n = 4) suffered major complications. Incidence of implant failure was 10.7% (n = 3). All reoperations were caused by infection. Mean varus alignment of the tibia and talus improved from 4.07 degrees and 4.83 degrees to 1.67 degrees and 1.23 degrees, respectively. Mean valgus alignment of the tibia and talus improved from 3.67 degrees and 4.22 degrees to 2.00 degrees and 2.32 degrees, respectively. Conclusions: In a series of 28 patients undergoing rTAA with the INVISION talar component, we discovered comparatively low rates of reoperation, major complication, and implant failure (10.7%, 14.3%, and 10.7%). The INVISION system appears to have a reasonable safety profile, but further studies evaluating long-term outcomes are required to assess the efficacy of the INVISION system.

Publisher

MDPI AG

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3