An Updated Evaluation of Intrathecal IgG Synthesis Markers in Relation to Oligoclonal Bands

Author:

Boufidou Fotini12ORCID,Vakrakou Aigli G.3,Anagnostouli Maria3ORCID,Patas Kostas2ORCID,Paraskevas Georgios4,Chatzipanagiotou Stylianos2,Stefanis Leonidas3,Evangelopoulos Maria-Eleftheria3

Affiliation:

1. Neurochemistry and Biological Markers Unit, 1st Department of Neurology, Eginition Hospital, Medical School, National and Kapodistrian University of Athens, 115 28 Athens, Greece

2. Department of Biopathology, Eginition Hospital, Medical School, National and Kapodistrian University of Athens, 115 28 Athens, Greece

3. 1st Department of Neurology, Eginition Hospital, Medical School, National and Kapodistrian University of Athens, 115 28 Athens, Greece

4. 2nd Department of Neurology, Attikon University Hospital, Medical School, National and Kapodistrian University of Athens, 12462 Athens, Greece

Abstract

The aim was to evaluate the performance of the latest quantitative marker for intrathecal IgG synthesis and to compare it with other established markers used for the same purpose. We retrospectively applied Auer’s and Reiber’s intrathecal IgG synthesis formulae in a cohort of 372 patients under investigation for central nervous system demyelination who had undergone lumbar puncture and oligoclonal bands (OCBs) detection for demonstrating intrathecal IgG synthesis. A ROC analysis revealed Auer’s formula had lower sensitivity (68%) compared to Reiber’s formula (83%) and IgG index (89%), in our cohort of patients that exhibited normal to mildly elevated albumin quotients (4.48 ± 3.93). By excluding possible sources of errors, we assume that Auer’s formula is less sensitive than other established tools for the “prediction” of the detection of OCBs in routine cerebrospinal fluid (CSF) analyses due to the mathematical model used. Given the ability of Reiber’s hyperbolic formula to describe the blood–CSF IgG distribution across a wide range of blood–brain barrier functionality, its use and the use of similar formulae are recommended for the discrimination between CNS-derived and blood-derived molecules in clinical laboratories.

Publisher

MDPI AG

Subject

Clinical Biochemistry

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3