Can the ADC Value Be Used as an Imaging “Biopsy” in Endometrial Cancer?

Author:

Petrila Octavia12,Nistor Ionut13,Romedea Narcis Sandy4,Negru Dragos5,Scripcariu Viorel16

Affiliation:

1. Faculty of General Medicine, The University of Medicine and Pharmacy “Grigore T. Popa”, 700115 Iasi, Romania

2. Department of Radiology, “Dr. C.I. Parhon” Clinical Hospital, 700503 Iasi, Romania

3. Department of Nephrology, “Dr. C.I. Parhon” Clinical Hospital, 700503 Iasi, Romania

4. Department of Surgery, “Dr. Iacob Czihac” Clinical Emergency Hospital, 700506 Iasi, Romania

5. Arcadia Medical Center, 700452 Iasi, Romania

6. Department of Surgery, Regional Oncology Institute, 700483 Iasi, Romania

Abstract

Background: The tumor histological grade is closely related to the prognosis of patients with endometrial cancer (EC). Multiparametric MRI, including diffusion-weighted imaging (DWI), provides information about the cellular density that may be useful to differentiate between benign and malignant uterine lesions. However, correlations between apparent diffusion coefficient (ADC) values and histopathological grading in endometrial cancer remain controversial. Material and methods: We retrospectively evaluated 92 patients with endometrial cancers, including both endometrioid adenocarcinomas (64) and non-endometrioid adenocarcinomas (28). All patients underwent DWI procedures, and mean ADC values were calculated in a region of interest. These values were then correlated with the tumor grading offered by the histopathological examination, which was considered the gold standard. In this way, the patients were divided into three groups (G1, G2, and G3). The ADC values were then compared to the results offered by the biopsy to see if the DWI sequence and ADC map could replace this procedure. We also compared the mean ADC values to the myometrial invasion (</>50%) and lymphovascular space invasion. Results: We have divided the ADC values into three categories corresponding to three grades: >0.850 × 10−3 mm2/s (ADC1), 0.730–0.849 × 10−3 mm2/s (ADC2) and <0.730 × 10−3 mm2/s (ADC3). The diagnostic accuracy of the ADC value was 85.71% for ADC1, 75.76% for ADC2, and 91.66% for ADC3. In 77 cases out of 92, the category in which they were placed using the ADC value corresponded to the result offered by the histopathological exam with an accuracy of 83.69%. For only 56.52% of patients, the biopsy result included the grading system. For each grading category, the mean ADC value showed better results than the biopsy; for G1 patients, the mean ADC value had an accuracy of 85.71% compared to 66.66% in the biopsy, G2 had 75.76% compared to 68.42%, and G3 had 91.66 compared to 75%. For both deep myometrial invasion and lymphovascular space invasion, there is a close, inversely proportional correlation with the mean ADC value. Conclusions: Mean endometrial tumor ADC on MR-DWI is inversely related to the histological grade, deep myometrial invasion and lymphovascular space invasion. Using this method, the patients could be better divided into risk categories for personalized treatment.

Publisher

MDPI AG

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3