The Visual Patient Avatar ICU Facilitates Information Transfer of Written Information by Visualization: A Multicenter Comparative Eye-Tracking Study

Author:

Viautour Julie1,Naegeli Lukas2,Braun Julia3ORCID,Bergauer Lisa1,Roche Tadzio1ORCID,Tscholl David1ORCID,Akbas Samira1ORCID

Affiliation:

1. Institute of Anesthesiology, University Hospital Zurich, Raemistrasse 100, 8091 Zurich, Switzerland

2. Master Program in Biostatistics, Epidemiology, Biostatistics and Prevention Institute, University of Zurich, Hirschengraben 84, 8001 Zurich, Switzerland

3. Departments of Epidemiology and Biostatistics, Epidemiology, Biostatistics and Prevention Institute, University of Zurich, Hirschengraben 84, 8001 Zurich, Switzerland

Abstract

Patient monitoring is crucial in critical care medicine. Perceiving and interpreting multiple vital signs requires a high workload that can lead to decreased situation awareness and consequently inattentional blindness, defined as impaired perception of unexpectedly changing data. To facilitate information transfer, we developed and validated the Visual-Patient avatar. Generated by numerical data, the animation displays the status of vital signs and patient installations according to a user-centered design to improve situation awareness. As a surrogate parameter for information transfer in patient monitoring, we recorded visual attention using eye-tracking data. In this computer-based study, we compared the correlation of visually perceived and correctly interpreted vital signs between a Visual-Patient-avatar ICU and conventional patient monitoring. A total of 50 recruited study participants (25 nurses, 25 physicians) from five European study centers completed five randomized scenarios in both modalities. Using a stationary eye tracker as the primary endpoint, we recorded how long different areas of interest of the two monitoring modalities were viewed. In addition, we tested for a possible association between the length of time an area of interest was viewed and the correctness of the corresponding question. With the conventional monitor, participants looked at the installation site the longest (median 2.13–2.51 s). With the Visual-Patient-avatar ICU, gaze distribution was balanced; no area of interest was viewed for particularly long. For both modalities, the longer an area was viewed, the more likely the associated question was answered incorrectly (OR 0.97, 95% CI 0.95–0.99, p = 0.008). The Visual-Patient-avatar ICU facilitates and improves information transfer through its visualizations, especially with written information. The longer an area of interest was viewed, the more likely the associated question was answered incorrectly.

Publisher

MDPI AG

Subject

Clinical Biochemistry

Reference35 articles.

1. World Health Organization-World Federation of Societies of Anaesthesiologists (WHO-WFSA) International Standards for a Safe Practice of Anesthesia;Gelb;Can. J. Anaesth.,2018

2. Size and distribution of the global volume of surgery in 2012;Weiser;Bull. World Health Organ.,2016

3. Situation awareness in anesthesia: Concept and RESEARCH;Schulz;Anesthesiology,2013

4. Endsley, M.R. (2012). Designing for Situation Awareness: An Approach to User-Centered Design, CRC Press.

5. What we see: Inattention and the capture of attention by meaning;Mack;Conscious Cogn.,2002

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献