Computer-Aided Assessment of Three-Dimensional Standard Bone Morphology of the Distal Radius

Author:

Ikumi AkiraORCID,Yoshii YuichiORCID,Eda YusukeORCID,Ishii Tomoo

Abstract

The present study attempted to define the three-dimensional (3D) locations of reference points and standard measures of the distal radius of a normal wrist joint. One hundred wrists from 50 males and 50 females who matched the age distribution (19–95 years old, mean: 56.0 years old) were evaluated. Computed tomography (CT) images of normal wrist joints acquired for comparison with the affected side were used. The absence of a previous history and complaints in the unaffected wrist was confirmed in an interview and with medical records. Three-dimensional images of the distal radius were reconstructed using the data obtained from CT scans. The site at which the major axis of the radial diaphysis contacted the distal radius joint surface was defined as the origin. The 3D coordinates of reference points for the radial styloid process (1), sigmoid notch volar edge (2), and sigmoid notch dorsal edge (3) as well as the barycenter for the joint surface and joint surface area were evaluated. A slope of the line connecting coordinates 1–2 in the coronal plane was evaluated as the 3D radial inclination (3DRI) and that connecting coordinates 2–3 in the sagittal plane as the 3D palmar tilt (3DPT). Each measurement value was compared between males and females. The positions of each reference point from the origin were as follows: (1) 14.2 ± 1.3/12.6 ± 1.1 mm for the distal-palmar-radial position; (2) 19.3 ± 1.3/16.9 ± 1.3 mm for the proximal-palmar-ulnar position; (3) 15.6 ± 1.4/14.1 ± 0.9 mm for the proximal-dorsal-ulnar position; and (barycenter) 4.1 ± 0.7/3.7 ± 0.7 mm for the proximal-volar-ulnar position for males and females, respectively. The areas of the radius articular surface were 429.0 ± 67.9/347.6 ± 44.6 mm2 for males and females, respectively. The 3DRI and 3DPT were 24.2 ± 4.0/25.7 ± 3.1° and 10.9 ± 5.1/13.2 ± 4.4° for males and females, respectively. Significant differences were observed in all measurement values between males and females (p < 0.01). The reference points and measured values obtained in the present study will serve as criteria for identifying the dislocation direction and reduction conditions of distal radius fractures in 3D images.

Funder

Grant-in-Aid for Scientific Research

AMED

ational Mutual Insurance Federation of Agricultural Cooperatives

Publisher

MDPI AG

Subject

Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3