A Pilot Study on the Reliability of Ultrasound-Based Assessment of Patella Diameter and Sulcus Angle

Author:

Schlüter Isa-Maria,Prill RobertORCID,Królikowska AleksandraORCID,Cruysen Caren,Becker Roland

Abstract

This pilot study aimed to determine the reliability of a newly developed ultrasound-based protocol for the assessment of patella diameter and sulcus angle. The diameter of the patella expressed in mm and the sulcus angle, expressed in degrees were measured in the right knee in 12 healthy participants (eight women and four men) in two separate sessions by two examiners (experienced rater and inexperienced rater) using ultrasonography according to a developed standardized protocol. The reliability was determined on the calculated intraclass correlation coefficient, ICC, expressed as a 95% confidence interval (lower bound, upper bound). For the patella diameter measurement, intra-rater and inter-rater reliability were good to excellent, with the ICC exceeding 0.836–0.998 and 0.859–0.997, respectively. The intra-rater and inter-rater reliability of the sulcus measurement was moderate to excellent, as the ICC amounted to 0.559–0.993 and 0.559–0.990, respectively. The reliability of both measures increased with the experience of the examiner. Therefore, it was determined that the newly developed protocol for an ultrasound-based assessment of patella diameter and sulcus angle is reliable. Further studies validating their clinical use should be carried out.

Funder

MHB publication fund

Publisher

MDPI AG

Subject

Clinical Biochemistry

Reference29 articles.

1. Gutachterliche Bewertung der Patellaluxation;Strich;Med. Sach.,2017

2. Wolfe, S., Varacallo, M., Thomas, J.D., Carroll, J.J., and Kahwaji, C.I. (2021). StatPearls, StatPearls Publishing.

3. Schmeling, A. (2010). Jahresausgabe der SFA Aktuell, Stifung zur Förderung der Arthroskopie.

4. Factors of patellar instability: An anatomic radiographic study;Dejour;Knee Surg. Sports Traumatol. Arthrosc.,1994

5. Jagodzinski, M., Niemeyer, P., Zeichen, J., and Balcarek, P. (2022, September 14). S1 Leitlinie Patella-Luxation. Available online: https://docplayer.org/93005476-Patella-luxation-leitlinienreport.html.

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3