Ankle Joint MRI—Comparison of Image Quality and Effect of Sports-Related Stress

Author:

Gorzolla Robert A. J.1,Rolle Udo2ORCID,Vogl Thomas J.1

Affiliation:

1. Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt, Germany

2. Department of Paediatric Surgery and Paediatric Urology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt, Germany

Abstract

Objectives: The main aims of the study were the evaluation of stress-related effects (strenuous vs. non-strenuous sport vs. nonathletes) in stimulating or reducing influences on cartilage volume in the ankle joint and the evaluation of the image quality of a magnetic resonance imaging (MRI) device with a field strength of 3.0 Tesla compared to one of 1.5 Tesla. Methods: A total of 15 subjects (6 male, 9 female) aged 19–33 years participated voluntarily in this prospective study. The subjects were divided into three groups: high-performance athletes of the German Football Association (DFB) (football/soccer = strenuous sport), high-performance athletes of the German Swimming Association (DSV) (swimming = non-strenuous sport), and nonathletes. MRI was performed on both ankle joints of all subjects in the 1.5 T and 3.0 T MRI scanners using survey sequences, proton density sequences in the coronal and sagittal planes, and VIBE sequences. Using the images of both feet produced by VIBE sequences, the cartilages of the talus and tibia were manually circumscribed using a computer mouse in every third layer, and the volume was calculated. For qualitative assessment, blinded images were submitted to three radiologists with defined standards. The images were scored using a scale from 1 to 5. Results: Cartilage volume: The investigation and examination of the individual cartilage volumes by analysis of variance (ANOVA) showed no significant differences among the three groups. The effect intensities, as calculated by Cohen’s d, were right tibia (Tiri) = 2.5, left tibia (Tile) = 2.2, right talus (Tari) = 1.9, and left talus (Tale) = 1.6 in the strenuous sport versus nonstrenuous sport groups; Tiri = 0.8, Tile = 1.2, Tari = 0.4, and Tale = 0.5 in the strenuous sport versus nonathlete groups; and Tiri = 0.3, Tile = 0.2, Tari = 0.7, and Tale = 0.5 in the nonstrenuous sport versus nonathlete groups. Device comparison: In the investigation of each evaluated area on the 1.5 T and 3.0 T MR images by the Wilcoxon matched-pair test, significant differences were found for the cartilage–bone border (KKG = 0.002), cancellous bone (Sp = 0.001), medial ligamentous apparatus (mBa = 0.001), lateral ligamentous apparatus (lBa = 0.001), and adipose tissue (Fg = 0.002). Thus, there were significant differences in the assessment of the 1.5 T MRI and the 3.0 T MRI in all five evaluated areas. Conclusion: The study showed no significant difference in the volume of hyaline articular cartilage in the upper ankle joint among the high-performance strenuous DFB athlete, high-performance non-strenuous DSV athlete, and nonathlete groups. The 3.0 Tesla device offers significant advantages in image quality compared to the 1.5 Tesla device.

Publisher

MDPI AG

Subject

Clinical Biochemistry

Reference26 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3