Risk Factors and Interpretation of Inconclusive Endoscopic Ultrasound-Guided Fine Needle Aspiration Cytology in the Diagnosis of Solid Pancreatic Lesions

Author:

Bor Renáta1,Vasas Béla2,Fábián Anna1,Szűcs Mónika3ORCID,Bősze Zsófia1,Bálint Anita1,Rutka Mariann1,Farkas Klaudia1,Tóth Tibor1ORCID,Resál Tamás1,Bacsur Péter1ORCID,Molnár Tamás1,Szepes Zoltán1

Affiliation:

1. Department of Internal Medicine, Albert Szent-Györgyi Medical School, University of Szeged, H-6725 Szeged, Hungary

2. Department of Pathology, Albert Szent-Györgyi Medical School, University of Szeged, H-6725 Szeged, Hungary

3. Department of Medical Physics and Informatics, Albert Szent-Györgyi Medical School, University of Szeged, H-6720 Szeged, Hungary

Abstract

Background: The inconclusive cytological findings of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) remain a major clinical challenge and often lead to treatment delays. Methods: Patients who had undergone EUS-FNA sampling for solid pancreas lesions between 2014 and 2021 were retrospectively enrolled. The “atypical” and “non-diagnostic” categories of the Papanicolaou Society of Cytopathology System were considered inconclusive and the “negative for malignancy” category of malignancy was suspected clinically. We determined the frequency and predictors of inconclusive cytological finding. Results: A total of 473 first EUS-FNA samples were included, of which 108 cases (22.83%) were inconclusive. Significant increases in the odds of inconclusive cytological findings were observed for lesions with a benign final diagnosis (OR 11.20; 95% CI 6.56–19.54, p < 0.001) as well as with the use of 25 G FNA needles (OR 2.12; 95% CI 1.09–4.01, p = 0.023) compared to 22 G needles. Furthermore, the use of a single EUS-FNA technique compared to the combined use of slow-pull and standard suction techniques (OR 1.70; 95% CI 1.06–2.70, p = 0.027) and less than three punctures per procedure led to an elevation in the risk of inconclusive cytology (OR 2.49; 95% CI 1.49–4.14, p < 0.001). Risk reduction in inconclusive cytology findings was observed in lesions between 2–4 cm (OR 0.40; 95% CI 0.23–0.68, p = 0.001) and >4 cm (OR 0.16; 95% CI 0.08–0.31, p < 0.001) compared to lesions ≤2 cm. Conclusions: The more than two punctures per EUS-FNA sampling with larger-diameter needle (19 G or 22 G) using the slow-pull and standard suction techniques in combination may decrease the probability of inconclusive cytological findings.

Funder

research grants of the National Research, Development and Innovation Office

New National Excellence Program of the Ministry of Human Capacities

Janos Bolyai Research Grant

Géza Hetényi Research Grant

Publisher

MDPI AG

Subject

Clinical Biochemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3