Abstract
Background: To compare the diagnostic efficacy of digital breast tomosynthesis (DBT) and ultrasound across breast densities in women recalled for assessment. Methods: A total of 482 women recalled for assessment from January 2017 to December 2019 were selected for the study. Women met the inclusion criteria if they had undergone DBT, ultrasound and had confirmed biopsy results. We calculated sensitivity, specificity, PPV, and AUC for DBT and ultrasound. Results: In dense breasts, DBT showed significantly higher sensitivity than ultrasound (98.2% vs. 80%; p < 0.001), but lower specificity (15.4% vs. 55%; p < 0.001), PPV (61.3% vs. 71%; p = 0.04) and AUC (0.568 vs. 0.671; p = 0.001). In non-dense breasts, DBT showed significantly higher sensitivity than ultrasound (99.2% vs. 84%; p < 0.001), but no differences in specificity (22% vs. 33%; p = 0.14), PPV (69.2% vs. 68.8%; p = 0.93) or AUC (0.606 vs. 0.583; p = 0.57). Around 73% (74% dense and 71% non-dense) and 77% (81% dense and 72% non-dense) of lesions assigned a RANZCR 3 by DBT and ultrasound, respectively, were benign. Conclusion: DBT has higher sensitivity, but lower specificity and PPV than ultrasound in women with dense breasts recalled for assessment. Most lesions rated RANZCR 3 on DBT and ultrasound are benign and may benefit from short interval follow-up rather than biopsy.
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献