Handheld Echocardiography Measurements Concordance and Findings Agreement: An Exploratory Study

Author:

Haji-Hassan Mariam1,Duțu Bogdan2,Bolboacă Sorana D.1ORCID

Affiliation:

1. Department of Medical Informatics and Biostatistics, “Iuliu Hațieganu” University of Medicine and Pharmacy Cluj-Napoca, Louis Pasteur Str., No. 6, 400349 Cluj-Napoca, Romania

2. Cardiology Section, Clinical Rehabilitation Hospital, Viilor Str., No. 46-50, 400437 Cluj-Napoca, Romania

Abstract

The professional association has already developed guidelines on the appropriate use of handheld ultrasound devices, especially in an emergency setting. Handheld ultrasound devices are seen as the ‘stethoscope of the future’ to assist in physical examination. Our exploratory study evaluated whether the measurements of cardiovascular structures and the agreement in identifying aortic, mitral, and tricuspid valve pathology made by a resident with a handheld device (HH, Kosmos Torso-One) reach the results reported by an experienced examiner who used a high-end device (STD). Patients referred for cardiology examination in a single center from June to August 2022 were eligible for the study. Patients who agreed to participate underwent two heart ultrasound examinations scanned by the same two operators. A cardiology resident performed the first examination with a HH ultrasound device, and an experienced examiner performed the second examination with an STD device. Forty-three consecutive patients were eligible, and forty-two were included in the study. One obese patient was excluded because none of the examiners succeeded in performing the heart examination. The measurements obtained with HH were generally higher than those obtained with STD, with the highest mean difference of 0.4 mm, but without significant differences (all 95% confidence intervals of the differences contain the value of 0). For valvular disease, the lowest agreement was observed for mitral valve regurgitation (26/42, with a Kappa concordance coefficient of 0.5321), which was missed in almost half of the patients with mild regurgitation and underestimated in half of the patients with moderate mitral regurgitation. The measurements performed by the resident with the handheld Kosmos Torso-One device showed high concordance with those conducted by the experienced examiner with a larger high-end ultrasound device. The learning curve of the resident could explain the limited performance in identifying valvular pathologies between examiners.

Publisher

MDPI AG

Subject

Clinical Biochemistry

Reference30 articles.

1. Omerovic, S., and Jain, A. (2022, September 02). Echocardiogram, StatPearls, Available online: https://www.ncbi.nlm.nih.gov/books/NBK558940/.

2. EACVI appropriateness criteria for the use of transthoracic echocardiography in adults: A report of literature and current practice review;Steeds;Eur. Heart J.-Cardiovasc. Imaging,2017

3. Handheld ultrasound in training—The future is getting smaller!;Wilkinson;J. Intensiv. Care Soc.,2020

4. The rate at which residents learn to use hand-held echocardiography at the bedside;Hellmann;Am. J. Med.,2005

5. Usefulness of Hand-Held Ultrasonography as a Gatekeeper to Standard Echocardiography for “Rarely Appropriate” Echocardiography Requests;Pathan;Am. J. Cardiol.,2016

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别