Evaluation of Breast Galactography Using Digital Breast Tomosynthesis: A Clinical Exploratory Study

Author:

Tao JuanORCID,Liao HaoORCID,Liu Yuan,Peng Qingsong,Zhu WenyingORCID,Peng ShuyiORCID,Liu Jie,Chen LeqingORCID,Yang Fan

Abstract

Objectives: To compare the application value of digital breast tomosynthesis (DBT) and full-field digital mammography (FFDM) in breast galactography. Materials and Methods: A total of 128 patients with pathological nipple discharge (PND) were selected to undergo galactography. DBT and FFDM were performed for each patient after injecting the contrast agent; the radiation dose of DBT and FFDM was calculated, and the image quality was evaluated in consensus by two senior breast radiologists. Histopathologic data were found in 49 of the 128 patients. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for both FFDM- and DBT-galactography were calculated using histopathologic results as a reference standard. Data were presented as percentages along with their 95% confidence intervals (CI). Results: The average age of the 128 patients was 46.53 years. The average glandular dose (AGD) of DBT-galactography was slightly higher than that of FFDM-galactography (p < 0.001). DBT-galactography was 30.7% higher than FFDM-galactography in CC view, while DBT-galactography increased by 21.7% compared with FFDM-galactography in ML view. Regarding catheter anatomic distortion, structure detail, and overall image quality groups, DBT scores were higher than FFDM scores, and the differences were significant for all measures (p < 0.05). In 49 patients with pathological nipple discharge, we found that the DBT-galactography had higher sensitivity, specificity, PPV, and NPV (93.3%, 75%, 97.7%, and 50%, respectively) than FFDM-galactography (91.1%, 50%, 95.3%, and 33.3%, respectively). Conclusions: Compared to FFDM-galactography, within the acceptable radiation dose range, DBT-galactography increases the sensitivity and specificity of lesion detection by improving the image quality, providing more confidence for the diagnosis of clinical ductal lesions.

Publisher

MDPI AG

Subject

Clinical Biochemistry

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3