Evaluation of the Reliability, Reproducibility and Validity of Digital Orthodontic Measurements Based on Various Digital Models among Young Patients

Author:

Park Seo-Hyun,Byun Soo-Hwan,Oh So-Hee,Lee Hye-Lim,Kim Ju-Won,Yang Byoung-EunORCID,Park In-Young

Abstract

The advantages of intraoral model scanning have yielded recent developments. However, few studies have explored the orthodontic clinical use of this technique particularly among young patients. This study aimed to evaluate the reliability, reproducibility and validity of the orthodontic measurements: tooth width, arch length and arch length discrepancy in each digital model obtained by model scanner and intraoral scanner, relative to a plaster model. Arch length measured using two methods: curved arch length (CAL) measured automatically by digital program and sum of sectional liner arch length (SLAL) measured sum of anterior and posterior liner arch lengths. Arch length discrepancy calculated each arch length measurement methods: curved arch length discrepancy (CALD) and sum of sectional liner arch length discrepancy (SLALD). Forty young patients were eligible for the study. A plaster model (P), model-scanned digital model (MSD) and intraoral scanned digital model (ISD) were acquired from each patient. The reliability of the measurements was evaluated using Pearson’s correlation coefficient, while the reproducibility was evaluated using the intraclass correlation coefficient. The validity was assessed by a paired t-test. All measurements measured in P, MSD and ISD exhibited good reliability and reproducibility. Most orthodontic measurements despite of CAL in MSD exhibited high validity. Only the SLAL and SLALD in ISD group differed significantly, despite the good validity of the tooth width, CAL and CALD. The measurements based on the digital program appeared high reliability, reproducibility and accurate than conventional measurement. However, SLAL and SLALD in ISD group appeared shorter because of distortion during intraoral scanning. However, this could be compensated by using digital programed curved arch. Although the validity of SLAL and SLALD in the ISD group differed statistically, the difference is not considered clinically significant. Although MSD and ISD are acceptable for a clinical space analysis, clinicians should be aware of digital model-induced errors.

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3