Assessment of Esophageal Shifts during Catheter Ablation of Atrial Fibrillation Using Intracardiac Ultrasound Integrated with 3-Dimensional Electroanatomical Mapping System

Author:

Pernat Andrej1,Zavrtanik Mark1,Robles Antonio Gianluca123ORCID,Romano Silvio2,Sciarra Luigi2ORCID,Antolič Bor1ORCID

Affiliation:

1. Department of Cardiology, University Medical Centre Ljubljana, 1000 Ljubljana, Slovenia

2. Department of Life, Health and Environmental Sciences, University of L’Aquila, 67100 L’Aquila, Italy

3. Department of Cardiology, “L. Bonomo” Hospital, ASL BAT, 76123 Andria, Italy

Abstract

Purpose: Atrioesophageal fistula is one of the most feared complications of radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF) as it is associated with high mortality. Determining the esophagus location during RFCA might reduce the risk of esophageal injury. The present study aims to evaluate the feasibility of using intracardiac echocardiography integrated into a 3-dimensional electroanatomical mapping system (ICE/3D EAM) for the assessment of esophageal position and shifts in response to ablation. Methods: We prospectively enrolled 20 patients that underwent RFCA of AF under conscious analgosedation. The virtual anatomy of the left atrium, the pulmonary vein (PV) ostia, and the esophagus was created with ICE/3D EAM. The esophageal positions were obtained at the beginning of the procedure and then after left and right PV isolation (PVI). Esophageal shifts were measured offline after the procedure using the tools available in the 3D EAM system. Results: Most esophagi moved away from the ablated PV ostia. After the left PVI, the median of the shifts was 2.8 mm (IQR 1.0–6.3). In 25% of patients, the esophagus shifted by >5.0 mm (max. 13.4 mm). After right PVI, the median of shifts was 2.0 mm (IQR 0.7–4.9). In 10% of patients, the esophageal shift was >5.0 mm (max. 7.8 mm). Conclusions: ICE/3D EAM enables the intraprocedural visualization of baseline esophageal position and its shifts after PVI. The shifts are variable, but they tend to be small and directed away from the ablation site. Repeated intraprocedural visualization of the esophagus may be needed to reduce the risk of esophageal injury.

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3