Trans-Scleral Plugs Fixated FIL SSF IOL: A Review of the Literature and Comparison with Other Secondary IOL Implants

Author:

Raimondi Raffaele1ORCID,Sorrentino Tania1,Kilian Raphael2,Verma Yash1ORCID,De Rosa Francesco Paolo1ORCID,Cancian Giuseppe1ORCID,Tsoutsanis Panos1ORCID,Fossati Giovanni1ORCID,Allegrini Davide3ORCID,Romano Mario R.13

Affiliation:

1. Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20090 Pieve Emanuele, Italy

2. Ophthalmic Unit, Department of Neurosciences, Biomedicine and Movement Sciences, University of Verona, 37129 Verona, Italy

3. Eye Center, Humanitas Gavazzeni-Castelli, 24128 Bergamo, Italy

Abstract

Purpose. To revise the current literature on FIL SSF (Carlevale) intraocular lens, previously known as Carlevale lens, and to compare their outcomes with those from other secondary IOL implants. Methods. We performed a peer review of the literature regarding FIL SSF IOLs until April 2021 and analyzed the results only of articles with a minimum of 25 cases and a follow-up of at least 6 months. The searches yielded 36 citations, 11 of which were abstracts of meeting presentations that were not included in the analysis because of their limited data. The authors reviewed 25 abstracts and selected six articles of possible clinical relevance to review in full text. Of these, four were considered to be sufficiently clinically relevant. Particularly, we extrapolated data regarding the pre- and postoperative best corrected visual acuities (BCVA) and the complications related to the procedure. The complication rates were then compared with those from a recently published Ophthalmic Technology Assessment by the American Academy of Ophthalmology (AAO) on secondary IOL implants. Results. Four studies with a total of 333 cases were included for results analysis. The BCVA improved in all cases after surgery, as expected. Cystoid macular edema (CME) and increased intraocular pressure were the most common complications, with an incidence of up to 7.4% and 16.5%, respectively. Other IOL types from the AAO report included anterior chamber IOLs, iris fixation IOLs, sutured iris fixation IOLs, sutured scleral fixation IOLs, and sutureless scleral fixation IOLs. There was no statistically significant difference in the rates of postoperative CME (p = 0.20), and vitreous hemorrhage (p = 0.89) between other secondary implants and the FIL SSF IOL, whereas the rate of retinal detachment was significantly less with FIL SSF IOLs (p = 0.04). Conclusion. The results of our study suggest the implantation of FIL SSF IOLs is an effective and safe surgical strategy in cases where there is a lack of capsular support. In fact, their outcomes seem to be comparable to those obtained with the other available secondary IOL implants. According to published literature, the FIL SSF (Carlevale) IOL provides favorable functional results with a low rate of postoperative complications.

Publisher

MDPI AG

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3