Cerclage Wiring Improves Biomechanical Stability in Distal Tibia Spiral Fractures Treated by Intramedullary Nailing

Author:

Förch Stefan1,Sandriesser Sabrina23,von Rüden Christian234ORCID,Mayr Edgar1,Augat Peter23

Affiliation:

1. Department of Trauma, Orthopaedic, Plastic and Hand Surgery, University Hospital of Augsburg, Stenglinstrasse 2, 86156 Augsburg, Germany

2. Institute for Biomechanics, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418 Murnau, Germany

3. Institute for Biomechanics, Paracelsus Medical University, Strubergasse 21, 5020 Salzburg, Austria

4. Department of Trauma Surgery, BG Unfallklinik Murnau, Prof. Küntscher Str. 8, 82418 Murnau, Germany

Abstract

Background: Partial weight-bearing after operatively treated fractures has been the standard of care over the past decades. Recent studies report on better rehabilitation and faster return to daily life in case of immediate weight-bearing as tolerated. To allow early weight-bearing, osteosynthesis needs to provide sufficient mechanical stability. The purpose of this study was to investigate the stabilizing benefits of additive cerclage wiring in combination with intramedullary nailing of distal tibia fractures. Methods: In 14 synthetic tibiae, a reproducible distal spiral fracture was treated by intramedullary nailing. In half of the samples, the fracture was further stabilized by additional cerclage wiring. Under clinically relevant partial and full weight-bearing loads the samples were biomechanically tested and axial construct stiffness as well as interfragmentary movements were assessed. Subsequently, a 5 mm fracture gap was created to simulate insufficient reduction, and tests were repeated. Results: Intramedullary nails offer already high axial stability. Thus, axial construct stiffness cannot be significantly enhanced by an additive cerclage (2858 ± 958 N/mm NailOnly vs. 3727 ± 793 N/mm Nail + Cable; p = 0.089). Under full weight-bearing loads, additive cerclage wiring in well-reduced fractures significantly reduced shear (p = 0.002) and torsional movements (p = 0.013) and showed similar low movements as under partial weight-bearing (shear 0.3 mm, p = 0.073; torsion 1.1°, p = 0.085). In contrast, additional cerclage had no stabilizing effect in large fracture gaps. Conclusions: In well-reduced spiral fractures of the distal tibia, the construct stability of intramedullary nailing can be further increased by additional cerclage wiring. From a biomechanical point of view, augmentation of the primary implant reduced shear movement sufficiently to allow immediate weight-bearing as tolerated. Especially, elderly patients would benefit from early post-operative mobilization, which allows for accelerated rehabilitation and a faster return to daily activities.

Publisher

MDPI AG

Subject

General Medicine

Reference38 articles.

1. Incidence and epidemiology of tibial shaft fractures;Larsen;Injury,2015

2. White, R., and Camuso, M. (2023, February 06). AO Surgery Reference-Intramedullary Nailing. Available online: https://surgeryreference.aofoundation.org/orthopedic-trauma/adult-trauma/tibial-shaft/simple-fracture-spiral/intramedullary-nailing#aftercare.

3. Influence of mobilization and weight bearing on in-hospital outcome in geriatric patients with hip fractures;Baer;SICOT J.,2019

4. Early versus delayed weight bearing after surgical fixation of distal femur fractures: A non-randomized comparative study;Consigliere;Eur. J. Orthop. Surg. Traumatol.,2019

5. Inability of Older Adult Patients with Hip Fracture to Maintain Postoperative Weight-Bearing Restrictions;Kammerlander;J. Bone Joint Surg. Am.,2018

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3