Responsiveness of Daily Life Gait Quality Characteristics over One Year in Older Adults Who Experienced a Fall or Engaged in Balance Exercise

Author:

Schootemeijer SabineORCID,Weijer Roel H. A.ORCID,Hoozemans Marco J. M.ORCID,Delbaere KimORCID,Pijnappels MirjamORCID,van Schooten Kimberley S.ORCID

Abstract

Gait quality characteristics obtained from daily-life accelerometry are clinically relevant for fall risk in older adults but it is unknown whether these characteristics are responsive to changes in gait quality. We aimed to test whether accelerometry-based daily-life gait quality characteristics are reliable and responsive to changes over one year in older adults who experienced a fall or an exercise intervention. One-week trunk acceleration data were collected from 522 participants (65–97 years), at baseline and after one year. We calculated median values of walking speed, regularity (sample entropy), stability (logarithmic rate of divergence per stride), and a gait quality composite score, across all 10-s gait epochs derived from one-week gait episodes. Intraclass correlation coefficients (ICC) and limits of agreement (LOA) were determined for 198 participants who did not fall nor participated in an exercise intervention during follow-up. For responsiveness to change, we determined the number of participants who fell (n = 209) or participated in an exercise intervention (n = 115) that showed a change beyond the LOA. ICCs for agreement between baseline and follow-up exceeded 0.70 for all gait quality characteristics except for vertical gait stability (ICC = 0.69, 95% CI [0.62, 0.75]) and walking speed (ICC = 0.68, 95% CI [0.62, 0.74]). Only walking speed, vertical and mediolateral gait stability changed significantly in the exercisers over one year but effect sizes were below 0.2. The characteristic associated with most fallers beyond the LOA was mediolateral sample entropy (4.8% of fallers). For the exercisers, this was gait stability in three directions and the gait quality composite score (2.6% of exercisers). The gait quality characteristics obtained by median values over one week of trunk accelerometry were not responsive to presumed changes in gait quality after a fall or an exercise intervention in older people. This is likely due to large (within subjects) differences in gait behaviour that participants show in daily life.

Funder

Dutch Organization for Scientific Research

AMS Innovation grant

Faculty of Behavioural and Movement Sciences

National Health and Medical Research Council

Human Frontier Science Program fellowship

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3