Author:
Zhang Xiufeng,Liang Long,Li Taiyou,Tan Jiakun,Liang Xingguo,Xie Guangyuan
Abstract
The real-time ash content measurement is the fundamental condition for the timely adjustment and intelligent control of operation parameters in coal production and utilization industry. In the present work, a real-time ash content analyzer based on the pseudo-dual energy X-ray transmission was developed. The feasibility of this X-ray ash content analyzer was validated by the linear relationship between ash content and five characteristic parameters of X-ray. The conditions of wave filter, tube voltage, and tube current were optimized. The comparison between the ash contents measured by muffle furnace and the X-ray ash content analyzer was conducted in laboratory and industry. It was found that the absolute error was smaller than 1% for clean coal with ash content of approximately 10%, and the possibility of the absolute error smaller than 0.5% was higher than 85%.
Funder
the Natural Science Foundation of Jiangsu Province
Subject
Geology,Geotechnical Engineering and Engineering Geology
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献