Abstract
This paper introduces an improved rotor braking protection circuit configuration and the corresponding self-adaptive control strategy to enhance the low voltage ride-through (LVRT) capability of the doubly-fed induction generator (DFIG). The proposed protection circuit consists of a crowbar circuit and a series rotor braking resistor array, which guarantees the safe operation of wind generators under the LVRT. Moreover, to adapt the proposed protection and further enhance the performance of the improved configuration, a corresponding self-adaptive control strategy is presented, which regulates the rotor braking resistor and protection exiting time automatically through calculating the rotor current in the fault period. The LVRT capability and transient performance of the DFIG by using the proposed method is tested with simulation. Compared with the conventional crowbar protection or the fixed rotor braking protection, the proposed protection and the control strategy present several advantages, such as retaining the control of the rotor side converter, avoiding repeated operation of the protection and accelerating the damping of stator flux linkage during a grid fault.
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
4 articles.