Modelling Polarization Effects in a CdZnTe Sensor at Low Bias
Author:
Pipek Jindřich1ORCID, Grill Roman1ORCID, Betušiak Marián1ORCID, Iniewski Kris2
Affiliation:
1. Institute of Physics, Faculty of Mathematics and Physics, Charles University, Ke Karlovu 5, CZ-121 16 Prague, Czech Republic 2. Redlen Technologies Inc., 1763 Sean Heights, Saanichton, BC V8M 0A5, Canada
Abstract
Semi-insulating CdTe and CdZnTe crystals fabricated into pixelated sensors and integrated into radiation detection modules have demonstrated a remarkable ability to operate under rapidly changing X-ray irradiation environments. Such challenging conditions are required by all photon-counting-based applications, including medical computed tomography (CT), airport scanners, and non-destructive testing (NDT). Although, maximum flux rates and operating conditions differ in each case. In this paper, we investigated the possibility of using the detector under high-flux X-ray irradiation with a low electric field satisfactory for maintaining good counting operation. We numerically simulated electric field profiles visualized via Pockels effect measurement in a detector affected by high-flux polarization. Solving coupled drift–diffusion and Poisson’s equations, we defined the defect model, consistently depicting polarization. Subsequently, we simulated the charge transport and evaluated the collected charge, including the construction of an X-ray spectrum on a commercial 2-mm-thick pixelated CdZnTe detector with 330 µm pixel pitch used in spectral CT applications. We analyzed the effect of allied electronics on the quality of the spectrum and suggested setup optimization to improve the shape of the spectrum.
Funder
Czech Science Foundation
Subject
Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry
Reference33 articles.
1. Hsieh, S., and Iniewski, K. (2023). Photon Counting Computed Tomography: Clinical Applications, Image Reconstruction and Material Discrimination, Springer International Publishing. [1st ed.]. 2. CdTe and CdZnTe Detectors in Nuclear Medicine;Scheiber;Nucl. Instrum. Methods Phys. Res. A,2000 3. Ashok, A., Gehm, M.E., and Greenberg, J.A. (2019, January 15–16). Combining Spatially and Energy-Resolved CdZnTe Detectors with Multiplexed Collimations to Improve Performance of X-ray Diffraction Systems for Baggage Scanning. Proceedings of the Anomaly Detection and Imaging with X-rays (ADIX) IV, Baltimore, MD, USA. 4. Contaminant Detection in Non-Destructive Testing Using a CZT Photon-Counting Detector;Richtsmeier;J. Instrum.,2021 5. Taguchi, K., Blevis, I., and Iniewski, K. (2022). Spectral, Photon Counting Computed Tomography: Technology and Applications, CRC Press.
|
|