Amniocentesis—When It Is Clear That It Is Not Clear

Author:

Ciortea Razvan,Malutan Andrei MihaiORCID,Bucuri Carmen ElenaORCID,Berceanu Costin,Rada Maria PatriciaORCID,Ormindean Cristina Mihaela,Mihu Dan

Abstract

A fetus identified to be at risk for chromosomal abnormalities may benefit from identification of genetic defects through amniocentesis. Although the risks associated with amniocentesis are considered to be minimal, being an invasive procedure it is not completely without complications. Background and Objectives: The current study aims to identify correlations between blood contamination of samples collected during amniocentesis and certain factors dependent on the instruments used (thickness of the needle used to aspirate the fluid), the location of the placenta, and uterine vascularity (more pronounced in multiparous patients). Materials and Methods: The study included 190 patients in the second trimester of pregnancy who met one of the criteria for invasive prenatal diagnosis (age over 35 years, high risk in first trimester screening, history of pregnancies with genetic abnormalities, etc.). The amniotic fluid samples collected from these patients were analyzed in terms of blood contamination of the amniotic fluid aspirated with maternal cells Results: Of the patients in whom the procedure was performed using 21 G size needles, 16 samples (13.33% of the total) were contaminated. None of the samples collected from patients where a 20 G needle was used were contaminated. There was a statistically significant association between the lack of contamination and the use of Doppler ultrasound in multiparous patients with anterior placenta in whom a 21-gauge needle was used for amniocentesis. Conclusions: There is an increased rate of sample contamination (statistically significant) when using 21 G needle sizes and a significant difference in contamination between primiparous and multiparous patients, with contamination being more frequent in multiparous patients. The use of Doppler ultrasonography may benefit the procedure, as the contamination rate was significantly reduced when used during amniocentesis.

Publisher

MDPI AG

Subject

General Medicine

Reference26 articles.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3