Transthoracic Impedance Measured with Defibrillator Pads—New Interpretations of Signal Change Induced by Ventilations

Author:

Berve Per OlavORCID,Irusta UnaiORCID,Kramer-Johansen JoORCID,Skålhegg Tore,Kongsgård Håvard Wahl,Brunborg Cathrine,Aramendi ElisabeteORCID,Wik Lars

Abstract

Compressions during the insufflation phase of ventilations may cause severe pulmonary injury during cardiopulmonary resuscitation (CPR). Transthoracic impedance (TTI) could be used to evaluate how chest compressions are aligned with ventilations if the insufflation phase could be identified in the TTI waveform without chest compression artifacts. Therefore, the aim of this study was to determine whether and how the insufflation phase could be precisely identified during TTI. We synchronously measured TTI and airway pressure (Paw) in 21 consenting anaesthetised patients, TTI through the defibrillator pads and Paw by connecting the monitor-defibrillator’s pressure-line to the endotracheal tube filter. Volume control mode with seventeen different settings were used (5–10 ventilations/setting): Six volumes (150–800 mL) with 12 min−1 frequency, four frequencies (10, 12, 22 and 30 min−1) with 400 mL volume, and seven inspiratory times (0.5–3.5 s ) with 400 mL/10 min−1 volume/frequency. Median time differences (quartile range) between timing of expiration onset in the Paw-line (PawEO) and the TTI peak and TTI maximum downslope were measured. TTI peak and PawEO time difference was 579 (432–723) m s for 12 min−1, independent of volume, with a negative relation to frequency, and it increased linearly with inspiratory time (slope 0.47, R 2 = 0.72). PawEO and TTI maximum downslope time difference was between −69 and 84 m s for any ventilation setting (time aligned). It was independent ( R 2 < 0.01) of volume, frequency and inspiratory time, with global median values of −47 (−153–65) m s , −40 (−168–68) m s and 20 (−93–128) m s , for varying volume, frequency and inspiratory time, respectively. The TTI peak is not aligned with the start of exhalation, but the TTI maximum downslope is. This knowledge could help with identifying the ideal ventilation pattern during CPR.

Funder

European Regional Development Fund

Euskal Herriko Unibertsitatea

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3