Abstract
The aim of this study was to analyze whether the respiratory variation in electrocardiogram (ECG) standard lead II R-wave amplitude (ΔRDII) could be used to assess intravascular volume status following inferior vena cava (IVC) clamping. This clamping causes an acute decrease in cardiac output during liver transplantation (LT). We retrospectively compared ΔRDII and related variables before and after IVC clamping in 34 recipients. Receiver operating characteristic (ROC) curve and area under the curve (AUC) analyses were used to derive a cutoff value of ΔRDII for predicting pulse pressure variation (PPV). After IVC clamping, cardiac output significantly decreased while ΔRDII significantly increased (p = 0.002). The cutoff value of ΔRDII for predicting a PPV >13% was 16.9% (AUC: 0.685) with a sensitivity of 57.9% and specificity of 77.6% (95% confidence interval 0.561 – 0.793, p = 0.015). Frequency analysis of ECG also significantly increased in the respiratory frequency band (p = 0.016). Although significant changes in ΔRDII during vena cava clamping were found at norepinephrine doses <0.1 µg/kg/min (p = 0.032), such changes were not significant at norepinephrine doses >0.1 µg/kg/min (p = 0.093). ΔRDII could be a noninvasive dynamic parameter in LT recipients presenting with hemodynamic fluctuation. Based on our data, we recommended cautious interpretation of ΔRDII may be requisite according to vasopressor administration status.
Funder
National Research Foundation of Korea
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献