Modeling and Design Enhancement of Electrothermal Actuators for Microgripping Applications

Author:

Pour Parham Dadash1ORCID,Ghommem Mehdi1ORCID,Abdelkefi Abdessattar2ORCID

Affiliation:

1. Mechanical Engineering Department, American University of Sharjah, Sharjah P.O. Box 26666, United Arab Emirates

2. Department of Mechanical and Aerospace Engineering, New Mexico State University, Las Cruces, NM 88003, USA

Abstract

Microgrippers are miniature tools that have the capability to handle and manipulate micro- and nano-scale objects. The present work demonstrates the potential impact of the incorporation of perforations on a ‘hot and cold arm’ electrothermal actuation mechanism in order to improve the operation of microgrippers in terms of arm opening and operating temperature. By applying a voltage to one arm and setting the other as a ground, the current passes through the electrothermal actuator and induces its displacement along the in-plane direction. The difference in the geometry of the two arms causes one arm to expand more than the other and this results in transverse bending. A computational model was developed using a finite element analysis tool to simulate the response of the thermal actuators with varying geometries and investigate the impact of incorporating perforations on the arms of the thermal actuators to enhance its performance in terms of deflection and operating temperature. The simulation results were compared to their experimental counterparts reported in the literature. A good agreement between the numerical and experimental data was obtained. A novel design of a microgripper, made of perforated electrothermal actuators, was introduced. Its main characteristics, including the tip opening of the gripper arms, the applied voltage, and the stress and temperature distributions, were analyzed using the developed computational model. Different perforation shape and distribution were investigated. The present study demonstrates the capability of perforations to enhance the operation of microgrippers as manifested by the obtained higher tip displacement and lower tip temperature in comparison to conventional microgripper designs made of non-perforated thermal actuators. Furthermore, the highest stress generated on the microgripper elements was found to be much lower than the yield strength of the constituent material, which indicates proper functioning without any mechanical failure.

Funder

American University of Sharjah

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3