Study on the Anti-Interference Performance of Substrate-Free PEDOT:PSS ECG Electrodes

Author:

Li Chunlin1ORCID,Xu Ke1,Chen Yuanfen1ORCID

Affiliation:

1. School of Mechanical Engineering, Guangxi University, Nanning 53004, China

Abstract

Substrate-free electrodes are promising dry electrodes for long-term physiological electrical signal monitoring due to their ultra-thinness, conformal contact, and stable skin–electrode impedance. However, the response of substrate-free electrodes to various disturbances during electrocardiogram (ECG) monitoring and the corresponding optimization needs to be investigated. This paper investigates the specific effects of various influencing factors on skin–electrode impedance and ECG during electrocardiogram (ECG) detection. The research utilizes substrate-free poly(3,4-ethylenedioxythiophene)/poly(styrene-sulfonate) (PEDOT:PSS) electrodes. The investigation employs several methods, including skin–electrode impedance comparison, ECG waveform analysis, spectrum analysis, and signal-to-noise ratio (SNR) evaluation. To avoid the impact of physiological state differences in subjects at different times, relevant data were only compared with the same group of experiments conducted in the same period. The results demonstrate that the substrate-free conformal contact PEDOT:PSS electrode has more stable skin–electrode impedance and could obtain a more stable ECG than partial contact electrodes (the SNR of the partial contact and conformal contact electrodes are 1.2768 ± 4.0299 dB and 7.2637 ± 1.4897 dB, respectively). Furthermore, the ECG signal quality of the substrate-free conformal contact PEDOT:PSS electrode was independent of the electrode area and shape (the SNRs of the large, medium, and small electrodes are 4.0447 ± 0.4616 dB, 3.9115 ± 0.5885 dB, and 4.1556 ± 0.5557 dB, respectively; the SNRs of the circular, square, and triangular electrodes are 9.2649 ± 0.6326 dB, 9.2471 ± 0.6806 dB, and 9.1514 ± 0.6875 dB, respectively), showing high signal acquisition capability that is the same as microneedle electrodes and better than fabric electrodes. The results of clothing friction effects show that skin–electrode impedance stability was important for ECG stability, while the impedance value was not (the SNRs of friction and non-friction electrodes are 2.4128 ± 7.0784 dB and 9.2164 ± 0.6696 dB, respectively). Moreover, the skin–electrode impedance maintains stability even at a high breathing frequency, but the ECG signal fluctuates at a high breathing frequency. This experiment demonstrates that even when the skin–electrode impedance remains stable, the ECG signal can still be susceptible to interference from other factors. This study suggests that substrate-free PEDOT:PSS that could form conformal contact with the skin has higher skin–electrode impedance stability and could measure a high ECG signal even with a small electrode area, demonstrating its potential as dry ECG electrodes, but the interference from other physiological electrical signals may require better circuit design.

Funder

National Natural Science Foundation of China

Publisher

MDPI AG

Reference34 articles.

1. Recent advances in electrochemical sensors and biosensors for monitoring drugs and metabolites in pharmaceutical and biological samples;Laghlimi;Admet Dmpk,2023

2. Fully Printed Electrodes on Stretchable Textiles for Long-Term Electrophysiology;Bihar;Adv. Mater. Technol.,2017

3. Fully printed all-polymer tattoo/textile electronics for electromyography;Bihar;Flex. Print. Electron.,2018

4. Five Day Attachment ECG Electrodes for Longitudinal Bio-Sensing Using Conformal Tattoo Substrates;Casson;IEEE Sens. J.,2017

5. Electrical bioadhesive interface for bioelectronics;Deng;Nat. Mater.,2020

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3