Abstract
The vibration serviceability of footbridges has evolved from the adoption of a single pedestrian crossing in the resonance condition to load cases in which several pedestrians cross the structure simultaneously. However, in spite of this improvement, pedestrians continue to be considered as applied loads in codes of practice. Recent research has pointed out that modeling pedestrians as dynamic systems is a step further in the search for a more realistic design approach. This is explored in this paper, focusing on the case of vertical vibration. A two-span cable-stayed test structure was selected, and accelerations were measured from single and group crossings, both at the structure and at a pedestrian’s waist. Numerical simulations considering the pedestrians modeled as loads only and also as dynamic systems were implemented, and numerical and experimental time response vibration signatures were compared. Reductions of up to 25% and 20% in peak and RMS acceleration, respectively, were obtained when pedestrians were modeled as dynamic systems, in comparison with the less realistic model of pedestrians as loads only. Such reductions were shown to depend on the number of pedestrians involved in the group. The results, thus, highlight that pedestrian–structure interaction is an asset for the vibration serviceability design of footbridges.