Determination of the Effect of a Thermal Curtain Used in a Greenhouse on the Indoor Climate and Energy Savings

Author:

Boyacı Sedat1,Atilgan Atilgan2ORCID,Kocięcka Joanna3ORCID,Liberacki Daniel3ORCID,Rolbiecki Roman4ORCID,Jagosz Barbara5ORCID

Affiliation:

1. Department of Biosystem Engineering, Faculty of Agriculture, Kırşehir Ahi Evran University, 40100 Kırşehir, Turkey

2. Department of Biosystems Engineering, Faculty of Engineering, Alanya Alaaddin Keykubat University, 07425 Alanya, Turkey

3. Department of Land Improvement, Environmental Development and Spatial Management, Poznań University of Life Sciences, 60-649 Poznań, Poland

4. Department of Agrometeorology, Plant Irrigation and Horticulture, Faculty of Agriculture and Biotechnology, Bydgoszcz University of Science and Technology, 85-029 Bydgoszcz, Poland

5. Department of Plant Biology and Biotechnology, University of Agriculture in Kraków, 31-120 Krakow, Poland

Abstract

In order to reduce the impact of outdoor extreme weather events on crop production in winter, energy saving in greenhouses that are regularly heated is of great importance in reducing production costs and carbon footprints. For this purpose, the variations in indoor temperature, relative humidity and dew point temperature in the vertical direction (2 m, 4 m, 5.7 m) of thermal curtains in greenhouses were determined. In addition, depending on the fuel used, the curtains’ effects on heat energy consumption, heat transfer coefficient, carbon dioxide equivalents released to the atmosphere and fuel cost were investigated. To reach this goal, two greenhouses with the same structural features were designed with and without thermal curtains. As a result of the study, the indoor temperature and relative humidity values in the greenhouse with a thermal curtain increased by 1.3 °C and 10% compared to the greenhouse without a thermal curtain. Thermal curtains in the greenhouse significantly reduced fuel use (59.14–74.11 m3·night−1). Considering the heat energy consumption, the average heat energy consumption was 453.7 kWh·night−1 in the greenhouse with a curtain, while it was 568.6 kWh·night−1 in the greenhouse without a curtain. The average heat transfer coefficient (U) values were calculated at 2.87 W·m−2 °C with a thermal curtain and 3.63 W·m−2 °C without a thermal curtain greenhouse. In the greenhouse, closing the thermal curtain at night resulted in heat energy savings of about 21%, related to the decrease in U values. The use of a thermal curtain in the greenhouse reduced the amount of CO2 released to the atmosphere (116.6–146.1 kg·night−1) and fuel cost (USD 21.3–26.7·night−1). To conclude, extreme weather events in the outdoor environment adversely affect the plants grown in greenhouses where cultivation is performed out of season. A thermal curtain, used to reduce these adverse effects and the amount of energy consumed, is essential in improving indoor climate conditions, providing more economical greenhouse management and reducing the CO2 released into the atmosphere due to fuel use.

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3