The rotating vortex rope, which can be decomposed in the rotating and the plunging modes, is the origin of pressure fluctuations in the draft tube cone when hydraulic turbines operate at part load, compromising the structural integrity and limiting the output load. A measurement campaign was carried out in a Kaplan turbine model which is a replica of the experimental 10 MW Porjus U9 prototype machine along a propeller curve to study the rotating vortex rope’s excitation levels and the induced structural responses. A complete set of sensors mounted on-board and off-board was used to measure pressures, forces, torques, accelerations, displacements, and strains. The characteristic frequencies and amplitudes of the pressure fluctuations and of the corresponding induced loads and vibrations associated with the two modes were quantified in a wide range of operating conditions at part load. The two modes are detected at different frequencies depending on the sensor position. Moreover, their frequencies change depending on the discharge and present different amplitudes depending on the mode. Particularly, the rotating mode shows higher amplitudes than the plunging mode in the majority of positions and directions measured.
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction