Simultaneous Measurement of Tricarboxylic Acid Cycle Intermediates in Different Biological Matrices Using Liquid Chromatography–Tandem Mass Spectrometry; Quantitation and Comparison of TCA Cycle Intermediates in Human Serum, Plasma, Kasumi-1 Cell and Murine Liver Tissue

Author:

Rathod RamjiORCID,Gajera Bharat,Nazir Kenneth,Wallenius Janne,Velagapudi Vidya

Abstract

The tricarboxylic acid (TCA) cycle is a central part of carbon and energy metabolism, also connecting to glycolysis, amino acid, and lipid metabolism. The quantitation of the TCA cycle intermediate within one method is lucrative due to the interest in central carbon metabolism profiling in cells and tissues. In addition, TCA cycle intermediates in serum have been discovered to correspond as biomarkers to various underlying pathological conditions. In this work, an Liquid Chromatography-Mass Spectrometry/Mass Spectrometry-based quantification method is developed and validated, which takes advantage of fast, specific, sensitive, and cost-efficient precipitation extraction. Chromatographic separation is achieved while using Atlantis dC18 2.1 mm × 100 mm, particle size 3-μm of Waters column with a gradient elution mobile phase while using formic acid in water (0.1% v/v) and acetonitrile. Linearity was clearly seen over a calibration range of: 6.25 to 6400 ng/mL (r2 > 0.980) for malic acid; 11.72 to 12,000 ng/mL (r2 > 0.980) for cis-aconitic acid and L-aspartic acid; 29.30 to 30,000 ng/mL (r2 > 0.980) for isocitric acid, l-serine, and l-glutamic acid; 122.07 to 125,000 ng/mL (r2 > 0.980) for citric acid, glycine, oxo-glutaric acid, l-alanine, and l-glutamine; 527.34 to 540,000 ng/mL (r2 > 0.980) for l-lactic acid; 976.56 to 1,000,000 ng/mL (r2 > 0.980) for d-glucose; 23.44 to 24,000 ng/mL (r2 > 0.980) for fumaric acid and succinic acid; and, 244.14 to 250,000 ng/mL (r2 > 0.980) for pyruvic acid. Validation was carried out, as per European Medicines Agency (EMA) “guidelines on bioanalytical method validation”, for linearity, precision, accuracy, limit of detection (LOD), limit of quantification (LLOQ), recovery, matrix effect, and stability. The recoveries from serum and tissue were 79–119% and 77–223%, respectively. Using this method, we measured TCA intermediates in serum, plasma (NIST 1950 SRM), and in mouse liver samples. The concentration found in NIST SRM 1950 (n = 6) of glycine (246.4 µmol/L), l-alanine (302.4 µmol/L), and serine (92.9 µmol/L).

Publisher

MDPI AG

Subject

Molecular Biology,Biochemistry,Endocrinology, Diabetes and Metabolism

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3