Tapered Optical Fiber Sensor Coated with Single-Walled Carbon Nanotubes for Dye Sensing Application

Author:

Polokhin Aleksandr A.1ORCID,Shaman Yuri P.2,Itrin Pavel A.3,Panyaev Ivan S.3ORCID,Sysa Artem A.2,Selishchev Sergey V.1,Kitsyuk Evgeny P.2ORCID,Pavlov Alexander A.4ORCID,Gerasimenko Alexander Yu.15ORCID

Affiliation:

1. Institute of Biomedical Systems, National Research University of Electronic Technology MIET, Shokin Square 1, 124498 Moscow, Russia

2. Scientific-Manufacturing Complex “Technological Centre”, Shokin Square 1, bld. 7 off. 7237, 124498 Moscow, Russia

3. S.P. Kapitsa Research and Technology Institute, Ulyanovsk State University, 42 Leo Tolstoy Str., 432017 Ulyanovsk, Russia

4. Institute of Nanotechnology of Microelectronics of the Russian Academy of Sciences, Leninsky Prospekt 32A, 119991 Moscow, Russia

5. Institute for Bionic Technologies and Engineering, I.M. Sechenov First Moscow State Medical University, Bolshaya Pirogovskaya Street 2-4, 119991 Moscow, Russia

Abstract

The present study aimed to improve the optical sensing performance of tapered optical fiber sensors toward aqueous Rhodamine B solution of different concentrations by applying single-walled carbon nanotubes (SWCNTs). The functional coating was formed on the surface of the tapered optical fiber sensor using an aerosol layer-by-layer deposition method. Before deposition, the SWCNTs were processed with multistage liquid-phase treatment in order to form a stable dispersion. The effect of SWCNT treatment was investigated through Raman spectroscopy. The deposition of 220 layers caused a reduction of up to 60% of the initial optical power of radiation propagating through the optical fiber core. The optical fiber sensor coated with SWCNTs demonstrated significantly higher sensitivity compared to a non-coated sensor in the range of 2–32 mg/L of Rhodamine B concentration in an aqueous solution. The experimental results demonstrated that the sensitivity was increased 10 times from 32 (mg/L)−1, for the non-coated sensor, up to 317 (mg/L)−1 after SWCNT coating deposition. Moreover, the SWCNT-coated sensor demonstrated high repeatability that allowed for the evaluation of the concentration regardless of the previously analyzed dye concentration.

Funder

Ministry of Science and Higher Education of the Russian Federation

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Mechanical Engineering,Control and Systems Engineering

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献