Percutaneous Approach in Endovascular Aortic Procedures Using a Suture-Mediated Closure Device

Author:

Oikonomou Kyriakos,Kvataia Akaki,Pfister Karin,Zygouridou Evgenia,Betz Thomas,Schierling WilmaORCID,Sachsamanis GeorgiosORCID

Abstract

Background: The purpose of this study is to assess the efficacy of a suture-mediated closure device during percutaneous endovascular aortic repair. Methods: A single-center, retrospective analysis of patients undergoing endovascular repair for infrarenal, thoracic and thoracoabdominal aortic aneurysms and aortic dissections via percutaneous femoral access between April 2017 and June 2021 was performed. The primary endpoint of the study was the efficacy and technical success of the Perclose ProGlide closure device during percutaneous endovascular procedures. The secondary endpoints were intraoperative and postoperative inguinal and vascular complications during and after device use. Results: A total of 376 punctures were performed in 263 patients with the deployment of the ProGlide vascular closure system. Twenty-two cases involved percutaneous re-puncture as part of a staged procedure. The primary and secondary technical success rates were 93.1% (350/376) and 94.7% (356/376), respectively. In 20 patients (5.3%), intraoperative femoral exposure due to complications was required. Postoperative complications occurred in 13 cases (3.5%), 2 of which required surgical reintervention. There was no statistical significance between the type of endovascular procedure and primary technical success (p = 0.56). The introduction of larger-diameter sheaths was not associated with increased intraoperative and postoperative complication rates (p = 0.75 and p = 0.78, respectively). Percutaneous re-puncture of the vascular access site did not result in a lower overall technical success rate (20/22, 90.9% primary technical success rate, p = 0.67; 21/22, 95.5% secondary technical success rate, p = 0.86) or an increased number of perioperative complications (1/22, 4.5% intraoperative complications, p = 0.86; 2/22, 9.1% postoperative complications, p = 0.13). Conclusion: The application of the ProGlide closure system is a safe and efficient method to achieve hemostasis during percutaneous endovascular aortic repair. Complex aortic pathologies, which often require a staged approach with re-puncture, can also be successfully treated with this closure system.

Publisher

MDPI AG

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3