Three-Dimensional Temperature Field Simulation and Analysis of a Concrete Bridge Tower Considering the Influence of Sunshine Shadow

Author:

Zou Shuai12,Xiao Jun134,Xian Jianping13,Zhang Yongshui2,Zhang Jingfeng4

Affiliation:

1. Shaanxi Union Research Center of University and Enterprise for Bridge Intelligent Construction, Xi’an 710199, China

2. School of Civil Engineering, Chongqing Jiaotong University, Chongqing 400074, China

3. CCCC Second Highway Engineering Co., Ltd., Xi’an 710065, China

4. School of Highway, Chang’an University, Xi’an 710064, China

Abstract

This paper forms a set of three-dimensional temperature field simulation methods considering the influence of sunshine shadow based on the DFLUX subroutine and FILM subroutine interface provided by the Abaqus platform to simulate the three-dimensional temperature field of concrete bridge towers and study its distribution law. The results show that the method has high accuracy for shadow recognition and temperature field calculation. The maximum difference between the shadow recognition results and the theoretical calculation value was only 19.1 mm, and the maximum difference between the simulated temperature and the measured temperature was 3.3 °C. The results of analyzing the temperature field of the concrete bridge tower using this algorithm show that the temperature difference between the opposite external surface of the tower column can reach 11.6 °C, which is significantly greater than the recommended temperature difference value of 5 °C in the specifications. For the concrete bridge tower, in the thickness direction of the tower wall, the temperature change was obvious only at a range of 0.3 m from the external surface of the tower wall, and the temperature change in the remaining range was small. In addition, the temperature gradient distribution of the sunshine temperature field in the direction of wall thickness conformed to the exponential function T(x) = T0e−αx + C. Additionally, the data fitting results indicate that using the temperature data at a distance of 0.8 m from the external surface as the calculation parameter in the function can achieve the ideal fitting result.

Funder

Science and Technology Project of the Shaanxi Department of Transportation

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Reference41 articles.

1. Tang, H. (2006). Study on Key Problems of Cable-Stayed Bridge PC Pylon. [Doctor’s Thesis, Southeast University].

2. Finite element analysis of thermal stress for cable-stayed bridge tower with cracks;Feng;Appl. Mech. Mater.,2012

3. Analysis of temperature field and thermal stress characteristics for a novel composite bridge tower catering for plateau environment;Zhang;Bridge Constr.,2020

4. Bridge monitoring: Application of the extreme function theory for damage detection on the I-40 case study;Martucci;Eng. Struct.,2023

5. A DBSCAN-based automated operational modal analysis algorithm for bridge monitoring;Civera;Measurement,2023